Selective determination of tryptophan by using a carbon paste electrode modified with an overoxidized polypyrrole film

被引:27
作者
Chen, ZD [1 ]
Okamura, K [1 ]
Hanaki, M [1 ]
Nagaoka, T [1 ]
机构
[1] Yamaguchi Univ, Fac Engn, Dept Appl Chem, Ube, Yamaguchi 7558611, Japan
关键词
D O I
10.2116/analsci.18.417
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report on the selective determination of tryptophan, using a carbon paste electrode coated with an overoxidized polypyrrole film. Out of 21 protein amino acids, only tryptophan and tyrosine exhibited an oxidative voltammetric response with this electrode. Tryptophan, which was preferentially concentrated to the electrode under an open circuit condition, was determined by the stripping voltammetric technique with a linear response range of 10-100 AM. For the determination of 10 muM tryptophan, interference from a 15-fold excess of tyrosine gave an positive error of 6%, while the other amino acids did not exhibit any detectable interference.
引用
收藏
页码:417 / 421
页数:5
相关论文
共 18 条
[1]   Copper dispersed into polyaniline films as an amperometric sensor in alkaline solutions of amino acids and polyhydric compounds [J].
Casella, IG ;
Cataldi, TRI ;
Guerrieri, A ;
Desimoni, E .
ANALYTICA CHIMICA ACTA, 1996, 335 (03) :217-225
[2]   DIFFUSIVE ANION-EXCHANGE IN POLYPYRROLE FILMS [J].
CURTIN, LS ;
KOMPLIN, GC ;
PIETRO, WJ .
JOURNAL OF PHYSICAL CHEMISTRY, 1988, 92 (01) :12-13
[3]   Potential-induced enantioselective uptake of amino acid into molecularly imprinted overoxidized polypyrrole [J].
Deore, B ;
Chen, ZD ;
Nagaoka, T .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :3989-3994
[4]   VOLTAMMETRIC DETERMINATION OF DOPAMINE IN THE PRESENCE OF ASCORBIC-ACID AT OVER-OXIDIZED POLYPYRROLE INDIGO CARMINE FILM-COATED ELECTRODES [J].
GAO, ZQ ;
CHEN, BS ;
ZI, MX .
ANALYST, 1994, 119 (03) :459-464
[5]   THE INFLUENCE OF OVEROXIDATION TREATMENT ON THE PERMEABILITY OF POLYPYRROLE FILMS [J].
GAO, ZQ ;
ZI, MX ;
CHEN, BS .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 373 (1-2) :141-148
[6]   ELECTROCHEMICAL PREPARATION AND ANALYTICAL APPLICATIONS OF ULTRATHIN OVEROXIDIZED POLYPYRROLE FILMS [J].
HSUEH, CC ;
BRAJTERTOTH, A .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :2458-2464
[7]   AMPEROMETRIC DETECTION OF AMINO-ACIDS IN A FLOW-INJECTION SYSTEM WITH A NICKEL(II)-MODIFIED ELECTRODE WITH AN EASTMAN-AQ POLYMER FILM [J].
LIU, AH ;
WANG, EK .
ANALYTICA CHIMICA ACTA, 1993, 280 (02) :223-229
[8]   CONSTANT POTENTIAL AMPEROMETRIC DETECTION OF UNDERIVATIZED AMINO-ACIDS AND PEPTIDES AT A COPPER ELECTRODE [J].
LUO, PF ;
ZHANG, FZ ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1702-1707
[9]  
MAHACHI TJ, 1986, J LIQ CHROMATOGR, V298, P297
[10]   DERIVATIZING REAGENTS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY DETECTION OF PEPTIDES AT THE PICOMOLE LEVEL [J].
MEEK, JL .
JOURNAL OF CHROMATOGRAPHY, 1983, 266 (AUG) :401-408