MR elastography of liver fibrosis: preliminary results comparing spin-echo and echo-planar imaging

被引:72
作者
Huwart, Laurent [1 ]
Salameh, Najat [1 ]
ter Beek, Leon [3 ]
Vicaut, Eric [2 ]
Peeters, Frank [1 ]
Sinkus, Ralph [4 ]
Van Beers, Bernard E. [1 ]
机构
[1] Catholic Univ Louvain, Diagnost Radiol Unit, St Luc Univ Hosp, B-1200 Brussels, Belgium
[2] Univ Paris Diderot, Hop Lariboisiere, Paris 7, France
[3] Philips Med Syst, Best, Netherlands
[4] Univ Paris Diderot, Lab Ondes & Acoust, Ecole Super Phys & Chim Ind Ville de Paris, Paris 7, France
关键词
Fibrosis; Liver cirrhosis; Elasticity; Magnetic resonance imaging; Echo-planar imaging;
D O I
10.1007/s00330-008-1051-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The purpose of this study was to prospectively compare the performance of magnetic resonance (MR) elastography using echo-planar and spin-echo imaging for staging of hepatic fibrosis. Twenty-four patients who had liver biopsy for suspicion of chronic liver disease had MR elastography performed with both spin-echo and echo-planar sequences. At histology, the fibrosis stage was assessed according to METAVIR. The data acquisition time was about 20 min using spin-echo, and only 2 min using echo-planar imaging. The hepatic signal-to-noise ratios were similar on both images (22.51 +/- 5.37 for spin-echo versus 21.02 +/- 4.76 for echo-planar, p=0.33). The elasticity measurements and the fibrosis stages were strongly correlated. The Spearman correlation coefficients were r=0.91 (p < 0.01) with spin-echo and r=0.84 (p < 0.01) with echo-planar sequences. These correlation coefficients did not differ significantly (p=0.17). A strong correlation was also observed between spin-echo and echo-planar elasticity (r=0.83, p < 0.001), without systematic bias. The results of our study showed that echo-planar imaging substantially decreased the data acquisition time of MR elastography, while maintaining the image quality and diagnostic performance for staging of liver fibrosis. This suggests that echo-planar MR elastography could replace spin-echo MR elastography in clinical practice.
引用
收藏
页码:2535 / 2541
页数:7
相关论文
共 26 条
[1]
An algorithm for the grading of activity in chronic hepatitis C [J].
Bedossa, P ;
Poynard, T .
HEPATOLOGY, 1996, 24 (02) :289-293
[2]
Sampling variability of liver fibrosis in chronic hepatitis C [J].
Bedossa, P ;
Dargère, D ;
Paradis, V .
HEPATOLOGY, 2003, 38 (06) :1449-1457
[3]
Current concepts: Liver biopsy. [J].
Bravo, AA ;
Sheth, SG ;
Chopra, S .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (07) :495-500
[4]
Practices of liver biopsy in France: Results of a prospective nationwide survey [J].
Cadranel, JF ;
Rufat, P ;
Degos, F .
HEPATOLOGY, 2000, 32 (03) :477-481
[5]
Prospective comparison of transient elastography, fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C [J].
Castéra, L ;
Vergniol, J ;
Foucher, J ;
Le Bail, B ;
Chanteloup, E ;
Haaser, M ;
Darriet, M ;
Couzigou, P ;
De Lédinghen, V .
GASTROENTEROLOGY, 2005, 128 (02) :343-350
[6]
Pain experienced during percutaneous liver biopsy [J].
Castéra, L ;
Nègre, I ;
Samii, K ;
Buffet, C .
HEPATOLOGY, 1999, 30 (06) :1529-1530
[7]
Diagnosis of cirrhosis by transient elastography (FibroScan):: a prospective study [J].
Foucher, J ;
Chanteloup, E ;
Vergniol, J ;
Castéra, L ;
Le Bail, B ;
Adhoute, X ;
Bertet, J ;
Couzigou, P ;
de Lédinghen, V .
GUT, 2006, 55 (03) :403-408
[8]
*FRENCH METAVIR CO, 1994, HEPATOLOGY, P15
[9]
Accuracy of liver stiffness measurement for the diagnosis of cirrhosis in patients with chronic liver diseases [J].
Ganne-Carrie, Nathahe ;
Ziol, Marianne ;
de Ledinghen, Victor ;
Douvin, Catherine ;
Marcellin, Patrick ;
Castera, Laurent ;
Dhumeaux, Daniel ;
Trinchet, Jean-Claude ;
Beaugrand, Michel .
HEPATOLOGY, 2006, 44 (06) :1511-1517
[10]
Rapid MR elastography using selective excitations [J].
Glaser, Kevin J. ;
Felmlee, Joel P. ;
Ehman, Richard L. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) :1381-1389