Rapid MR elastography using selective excitations

被引:17
作者
Glaser, Kevin J. [1 ]
Felmlee, Joel P. [1 ]
Ehman, Richard L. [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN USA
关键词
magnetic resonance elastography; selective excitation; tissue characterization; reduced FOV; beam elastography;
D O I
10.1002/mrm.20913
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Rapid MR elastography (MRE) techniques using spatially-selective excitations to reduce acquisition times to a few seconds or less were devised and tested. The techniques included reduced field of view (rFOV) MRE and ID MRE (beam MRE) using 2D spatially selective RF excitations for gradient-echo (GRE) applications and intersecting 90 degrees and 180 degrees slice-selective excitations for spin-echo (SE) applications. It was shown that scan times could be reduced by a factor of 8 using rFOV MRE, and by 64 using beam MRE, while still obtaining stiffness estimates comparable to full-FOV MRE. Results were shown in gel phantom experiments as well as in the case of a preserved postmortem breast tissue specimen with a stiff lesion. These methods can be used to more rapidly interrogate regions of interest (ROls) in tissue to quickly obtain information about the viscoelastic properties of that tissue.
引用
收藏
页码:1381 / 1389
页数:9
相关论文
共 51 条
[1]
Angiographic imaging with 2D RF pulses [J].
Alley, MT ;
Pauly, JM ;
Sommer, FG ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) :260-267
[2]
MR IMAGING OF MOTION WITH SPATIAL MODULATION OF MAGNETIZATION [J].
AXEL, L ;
DOUGHERTY, L .
RADIOLOGY, 1989, 171 (03) :841-845
[3]
In vivo breast tumor detection using transient elastography [J].
Bercoff, J ;
Chaffai, S ;
Tanter, M ;
Sandrin, L ;
Catheline, S ;
Fink, M ;
Gennisson, JL ;
Meunier, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (10) :1387-1396
[4]
Börnert P, 1998, MAGN RESON MATER PHY, V7, P166
[5]
Curved slice imaging [J].
Bornert, P ;
Schaffter, T .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :932-939
[6]
SCREENING MAMMOGRAPHY IN COMMUNITY PRACTICE - POSITIVE PREDICTIVE VALUE OF ABNORMAL FINDINGS AND YIELD OF FOLLOW-UP DIAGNOSTIC PROCEDURES [J].
BROWN, ML ;
HOUN, F ;
SICKLES, EA ;
KESSLER, LG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) :1373-1377
[7]
PHASE-VELOCITY MAPPING WITH A REAL-TIME LINE SCAN TECHNIQUE [J].
BUTTS, K ;
HANGIANDREOU, NJ ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) :134-138
[8]
Elasticity reconstructive imaging by means of stimulated echo MRI [J].
Chenevert, TL ;
Skovoroda, AR ;
O'Donnell, M ;
Emelianov, SY .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (03) :482-490
[9]
FAST MR CARDIAC PROFILING WITH 2-DIMENSIONAL SELECTIVE PULSES [J].
CLINE, HE ;
HARDY, CJ ;
PEARLMAN, JD .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :390-401
[10]
Ten-year risk of false positive screening mammograms and clinical breast examinations [J].
Elmore, G ;
Barton, MB ;
Moceri, VM ;
Polk, S ;
Arena, PJ ;
Fletcher, SW .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (16) :1089-1096