Tensile and compressive properties of healthy and osteoarthritic human articular cartilage

被引:35
作者
Boschetti, Federica [1 ,2 ]
Peretti, Giuseppe M. [3 ,4 ]
机构
[1] Politecn Milan, Dept Struct Engn, Lab Biol Struct Mech, I-20133 Milan, Italy
[2] IRCCS Ist Ortoped Galeazzi, Milan, Italy
[3] Univ Milan, Fac Exercise Sci, Milan, Italy
[4] Hosp San Raffaele, Dept Orthopaed, I-20132 Milan, Italy
关键词
Articular cartilage; poroelastic modeling; biomechanical tests; osteoarthritis;
D O I
10.3233/BIR-2008-0479
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Osteoarthritis (OA) is a disease affecting articular cartilage and the underlying bone, resulting from many biological and mechanical interacting factors which change the extracellular matrix (ECM) and cells and lead to increasing levels of cartilage degeneration, like softening, fibrillation, ulceration and cartilage loss. The early diagnosis of the disease is fundamental to prevent pain, further tissue degeneration and reduce hospital costs. Although morphological modifications can be detected by modern non-invasive diagnostic techniques, they may not be evident in the early stages of OA. The mechanical properties of articular cartilage are related to its composition and structure and are sensitive to even small changes in the ECM that could occur in early OA. The aim of the present study was to compare the mechanical properties of healthy and OA cartilage using a combined experimental-numerical approach. Experimental assessments consisted of step wise confined and unconfined compression and tension stress relaxation tests on disks (for compression) or strips (for tension) of cartilage obtained from human femoral heads discarded from the operating room after total hip replacement. The numerical model was based on the biphasic theory and included the tension-compression non-linearity. Considering OA samples vs normal samples, the static compressive modulus was 55-68% lower, the permeability was 60-80% higher, the dynamic compressive modulus was 59-64% lower, the static tension modulus was 72-83% lower. The model successfully simulated the experimental tests performed on healthy and OA cartilage and was used in combination with the experimental tests to evaluate the role of different ECM components in the mechanical response of normal and OA cartilage.
引用
收藏
页码:337 / 344
页数:8
相关论文
共 20 条
[1]   TENSILE PROPERTIES OF HUMAN KNEE-JOINT CARTILAGE .1. INFLUENCE OF IONIC CONDITIONS, WEIGHT BEARING, AND FIBRILLATION ON THE TENSILE MODULUS [J].
AKIZUKI, S ;
MOW, VC ;
MULLER, F ;
PITA, JC ;
HOWELL, DS ;
MANICOURT, DH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1986, 4 (04) :379-392
[2]   VARIATIONS IN THE INTRINSIC MECHANICAL PROTERTIES OF HUMAN ARTICULAR-CARTILAGE WITH AGE, DEGENERATION, AND WATER-CONTENT [J].
ARMSTRONG, CG ;
MOW, VC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (01) :88-94
[3]   THE EFFECTS OF SELECTIVE MATRIX DEGRADATION ON THE SHORT-TERM COMPRESSIVE PROPERTIES OF ADULT HUMAN ARTICULAR-CARTILAGE [J].
BADER, DL ;
KEMPSON, GE ;
EGAN, J ;
GILBEY, W ;
BARRETT, AJ .
BIOCHIMICA ET BIOPHYSICA ACTA, 1992, 1116 (02) :147-154
[4]  
Boschetti F, 2006, BIORHEOLOGY, V43, P235
[5]  
Buckwalter JA, 1998, AAOS INSTR COURS LEC, V47, P487
[6]   Changes in the stiffness of the human tibial cartilage-bone complex in early-stage osteoarthrosis [J].
Ding, M ;
Dalstra, M ;
Linde, F ;
Hvid, I .
ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (04) :358-362
[7]  
EBERLAIN R, 2000, COMPUT METHODS BIOME, V190, P4379
[8]   Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM) [J].
Eckstein, F ;
Gavazzeni, A ;
Sittek, H ;
Haubner, M ;
Losch, A ;
Milz, S ;
Englmeier, KH ;
Schulte, E ;
Putz, R ;
Reiser, M .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) :256-265
[9]   Joint injury in young adults and risk for subsequent knee and hip osteoarthritis [J].
Gelber, AC ;
Hochberg, MC ;
Mead, LA ;
Wang, NY ;
Wigley, FM ;
Klag, MJ .
ANNALS OF INTERNAL MEDICINE, 2000, 133 (05) :321-328
[10]   CORRELATIONS BETWEEN STIFFNESS AND CHEMICAL CONSTITUENTS OF CARTILAGE ON HUMAN FEMORAL HEAD [J].
KEMPSON, GE ;
MUIR, H ;
SWANSON, SAV ;
FREEMAN, MAR .
BIOCHIMICA ET BIOPHYSICA ACTA, 1970, 215 (01) :70-&