Regional pulmonary pressure volume curves in mechanically ventilated patients with acute respiratory failure measured by electrical impedance tomography

被引:44
作者
Hinz, J [1 ]
Moerer, O [1 ]
Neumann, P [1 ]
Dudykevych, T [1 ]
Frerichs, I [1 ]
Hellige, G [1 ]
Quintel, M [1 ]
机构
[1] Univ Gottingen, Dept Anaesthesiol Emergency & Intens Care Med, D-3400 Gottingen, Germany
关键词
electrical impedance tomography; lung mechanics; pressure volume curves; regional;
D O I
10.1111/j.1399-6576.2006.00958.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: We hypothized, that in mechanically ventilated patients with acute respiratory failure, regional pressure volume curves differ markedly from conventional global pressure volume curves of the whole lung. Methods: In nine mechanically ventilated patients with acute respiratory failure during an inspiratory low-flow manoeuvre, conventional global pressure volume curves were registered by spirometry and regional pressure volume curves in up to 912 regions were assessed simultaneously using electrical impedance tomography. We compared the lower (LIP) and upper (UIP) inflection points obtained from the conventional global pressure volume curve and regional pressure volume curves. Results: We identified from the conventional global pressure volume curves LIP [3-11 (8) cmH(2)O] in eight patients and UIP [31-39 (33) cmH(2)O] in three patients. Using electrical impedance tomography (EIT), LIP [3-18 (8) cmH(2)O] in 54-264 (180) regions and UIP [23-42 (36) cmH(2)O] in 149-324 (193) regions (range and median) were identified. Lung mechanics measured by conventional global pressure volume curves are similar to the median of regional pressure volume curves obtained by EIT within the tomographic plane. However, single regional pressure volume curves differ markedly with a broad heterogeneity of lower and upper inflection points. Conclusion: Lower and upper inflection points obtained from conventional global pressure volume curves are not representative of all regions of the lungs.
引用
收藏
页码:331 / 339
页数:9
相关论文
共 42 条
[1]   Tomographic study of the inflection points of the pressure-volume curve in acute lung injury [J].
Albaiceta, GM ;
Taboada, F ;
Parra, D ;
Luyando, LH ;
Calvo, J ;
Menendez, R ;
Otero, J .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 170 (10) :1066-1072
[2]   Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome [J].
Amato, MBP ;
Barbas, CSV ;
Medeiros, DM ;
Magaldi, RB ;
Schettino, GDP ;
Lorenzi, G ;
Kairalla, RA ;
Deheinzelin, D ;
Munoz, C ;
Oliveira, R ;
Takagaki, TY ;
Carvalho, CRR .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (06) :347-354
[3]   Electrical impedance tomography: On the path to the Holy Grail [J].
Arnold, JH .
CRITICAL CARE MEDICINE, 2004, 32 (03) :894-895
[4]   The American-European Consensus Conference on ARDS, Part 2 - Ventilatory, pharmacologic, supportive therapy, study design strategies and issues related to recovery and remodeling [J].
Artigas, A ;
Bernard, GR ;
Carlet, J ;
Dreyfuss, D ;
Gattinoni, L ;
Hudson, L ;
Lamy, M ;
Marini, JJ ;
Matthay, MA ;
Pinsky, MR ;
Spragg, R ;
Suter, PM ;
Marini, JJ ;
Dreyfuss, D ;
Blanch, L ;
Burchardi, H ;
Hedenstierna, G ;
Lemaire, F ;
Roussos, C ;
Mancebo, J ;
Morris, A ;
Pesenti, A ;
Rossi, A ;
Bernard, GR ;
Lamy, M ;
Van Asbeck, BS ;
Brigham, KL ;
Dhainaut, JF ;
Fowler, AA ;
Hyers, TM ;
Morel, D ;
Rodriguez-Roisin, R ;
Schaller, MD ;
Pinsky, MR ;
Suter, PM ;
Hemmer, M ;
Torres, A ;
Villar, J ;
Vincent, JL ;
Matthay, MA ;
Gattinoni, L ;
Leeper, K ;
Meyrick, B ;
Oppenheimer, L ;
Reid, L ;
Artigas, A ;
Carlet, J ;
Hudson, DL ;
Murray, JE ;
Spragg, R .
INTENSIVE CARE MEDICINE, 1998, 24 (04) :378-398
[5]   APPLIED POTENTIAL TOMOGRAPHY [J].
BARBER, DC ;
BROWN, BH .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (09) :723-733
[6]  
BROWN BH, 1987, MED PROG TECHNOL, V13, P69
[7]   Recruitment and derecruitment during acute respiratory failure - A clinical study [J].
Crotti, S ;
Mascheroni, D ;
Caironi, P ;
Pelosi, P ;
Ronzoni, G ;
Mondino, M ;
Marini, JJ ;
Gattinoni, L .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (01) :131-140
[8]   Electrical impedance tomography: a method for monitoring regional lung aeration and tidal volume distribution? [J].
Frerichs, I ;
Dargaville, PA ;
Dudykevych, T ;
Rimensberger, PC .
INTENSIVE CARE MEDICINE, 2003, 29 (12) :2312-2316
[9]   Detection of local lung air content by electrical impedance tomography compared with electron beam CT [J].
Frerichs, I ;
Hinz, J ;
Herrmann, P ;
Weisser, G ;
Hahn, G ;
Dudykevych, T ;
Quintel, M ;
Hellige, G .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (02) :660-666
[10]   PRESSURE-VOLUME CURVE OF TOTAL RESPIRATORY SYSTEM IN ACUTE RESPIRATORY-FAILURE - COMPUTED TOMOGRAPHIC SCAN STUDY [J].
GATTINONI, L ;
PESENTI, A ;
AVALLI, L ;
ROSSI, F ;
BOMBINO, M .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 136 (03) :730-736