Novel chloride-selective optode based on polymer-stabilised emulsions doped with a lipophilic fluorescent polarity-sensitive dye

被引:27
作者
Huber, C [1 ]
Werner, T [1 ]
Krause, C [1 ]
Wolfbeis, OS [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93040 Regensburg, Germany
关键词
D O I
10.1039/a905260g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chloride-selective optode is presented which is based on a polymer-stabilised emulsion system consisting of a hydrogel with entrapped plasticizer droplets. The droplets contain a neutral chloride-selective ionophore and a polarity-sensitive cationic fluorescent dye (PSD) located near the droplet surface. The ionophore extracts chloride out of the aqueous solution through the hydrogel into the plasticizer droplets, followed by a displacement of the positively charged PSD into the plasticizer droplet. This concerted process causes a decrease of micro-polarity near the dye, resulting in a dramatic increase in its fluorescence intensity. The sensing scheme can be used for reversible sensing of chloride in the 1-80 mM concentration range with response times on the order of less than 3 min. The sensor membrane has been investigated in terms of signal change, stability, limits of detection and selectivity for the analyte over interferents.
引用
收藏
页码:1617 / 1622
页数:6
相关论文
共 31 条
  • [21] Perrin D., 2012, Buffers for pH and metal ion control
  • [22] Response mechanism of anion-selective electrodes based on mercury organic compounds as ionophores
    Rothmaier, M
    Schaller, U
    Morf, WE
    Pretsch, E
    [J]. ANALYTICA CHIMICA ACTA, 1996, 327 (01) : 17 - 28
  • [23] CHLORIDE-SELECTIVE ELECTRODES BASED ON MERCURY ORGANIC-COMPOUNDS AS NEUTRAL CARRIERS
    ROTHMAIER, M
    SIMON, W
    [J]. ANALYTICA CHIMICA ACTA, 1993, 271 (01) : 135 - 141
  • [24] SCHWARZ C, 1995, J NEUROSCI, V15, P3475
  • [25] Stoy V A, 1989, J Biomater Appl, V3, P552
  • [26] TAN SSS, 1989, CHIMIA, V43, P257
  • [27] REVERSIBLE OPTICAL SENSING MEMBRANE FOR THE DETERMINATION OF CHLORIDE IN SERUM
    TAN, SSS
    HAUSER, PC
    WANG, KM
    FLURI, K
    SEILER, K
    RUSTERHOLZ, B
    SUTER, G
    KRUTTLI, M
    SPICHIGER, UE
    SIMON, W
    [J]. ANALYTICA CHIMICA ACTA, 1991, 255 (01) : 35 - 44
  • [28] TIETZ NW, 1976, FUNDAMENTALS CLIN CH, P879
  • [29] ANION-SELECTIVE OPTICAL SENSING WITH METALLOPORPHYRIN-DOPED POLYMERIC FILMS
    WANG, EJ
    MEYERHOFF, ME
    [J]. ANALYTICA CHIMICA ACTA, 1993, 283 (02) : 673 - 682
  • [30] Fiber optic ion-microsensors based on luminescence lifetime
    Werner, T
    Klimant, I
    Huber, C
    Krause, C
    Wolfbeis, OS
    [J]. MIKROCHIMICA ACTA, 1999, 131 (1-2) : 25 - 28