Electrochemical multianalyte immunoassays using an array-based sensor

被引:134
作者
Wilson, MS [1 ]
Nie, WY [1 ]
机构
[1] EIC Labs Inc, Norwood, MA 02062 USA
关键词
D O I
10.1021/ac0518452
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel amperometric biosensor for performing simultaneous electrochemical multianalyte immunoassays is described. The sensor consisted of eight iridium oxide sensing electrodes (0.78 mm(2) each), an iridium counter electrode, and a Ag/AgCl reference electrode patterned on a glass substrate. Four different capture antibodies were immobilized on the sensing electrodes via adsorption. Quantification of proteins was achieved using an ELISA in which the electrochemical oxidation of enzyme-generated hydroquinone was measured. The spatial separation of the electrodes enabled simultaneous electrochemical immunoassays for multiple proteins to be conducted in a single assay without amperometric crosstalk between the electrodes. The simultaneous detection of goat IgG, mouse IgG, human IgG, and chicken IgY was demonstrated. The detection limit was 3 ng/mL for all analytes. The sensor had excellent precision (1.9-8.2% interassay CV) and was comparable in performance to commercial single-analyte ELISAs. We anticipate that chip-based sensors, as described herein, will be suitable for the mass production of economical, miniaturized, multianalyte assay devices.
引用
收藏
页码:2507 / 2513
页数:7
相关论文
共 24 条
  • [1] Microfluidic immunosensor systems
    Bange, A
    Halsall, HB
    Heineman, WR
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) : 2488 - 2503
  • [2] Quantitative protein profiling using antibody arrays
    Barry, R
    Soloviev, M
    [J]. PROTEOMICS, 2004, 4 (12) : 3717 - 3726
  • [3] Multiplex diagnostic platforms for detection of biothreat agents
    Cirino, NM
    Musser, KA
    Egan, C
    [J]. EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2004, 4 (06) : 841 - 857
  • [4] Feasibility studies of simultaneous multianalyte amperometric immunoassay based on spatial resolution
    Ding, Y
    Zhou, LP
    Halsall, HB
    Heineman, WR
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (1-2) : 153 - 161
  • [5] SIMULTANEOUS IMMUNOASSAY USING ELECTROCHEMICAL DETECTION OF METAL-ION LABELS
    HAYES, FJ
    HALSALL, HB
    HEINEMAN, WR
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (11) : 1860 - 1865
  • [6] A polymer-based microfluidic device for immunosensing biochips
    Ko, JS
    Yoon, HC
    Yang, HS
    Pyo, HB
    Chung, KH
    Kim, SJ
    Kim, YT
    [J]. LAB ON A CHIP, 2003, 3 (02) : 106 - 113
  • [7] Electrochemical protein chip with arrayed immunosensors with antibodies immobilized in a plasma-polymerized film
    Kojima, K
    Hiratsuka, A
    Suzuki, H
    Yano, K
    Ikebukuro, K
    Karube, I
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (05) : 1116 - 1122
  • [8] KRICKA LJ, 1992, CLIN CHEM, V38, P327
  • [9] Protein patterning on silicon-based surface using background hydrophobic thin film
    Lee, CS
    Lee, SH
    Park, SS
    Kim, YK
    Kim, BG
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (04) : 437 - 444
  • [10] Array biosensor for detection of toxins
    Ligler, FS
    Taitt, CR
    Shriver-Lake, LC
    Sapsford, KE
    Shubin, Y
    Golden, JP
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (03) : 469 - 477