Image intensifier-based computed tomography volume scanner for angiography

被引:30
作者
Ning, R [1 ]
Kruger, RA [1 ]
机构
[1] INDIANA UNIV,MED CTR,DEPT RADIOL,INDIANAPOLIS,IN 46204
关键词
computed tomography; volume computed tomography; angiography; cone-beam reconstruction;
D O I
10.1016/S1076-6332(96)80255-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. A prototype volume computed tomography (CT) system for use in angiography was designed, constructed and tested. The system consisted of a fixed X-ray tube, a conventional image intensifier (II) coupled to a charge-coupled device camera, and a computer-controlled turntable on which phantoms were placed, We wanted to predict, through phantom studies, the imaging performance of an II-based volume CT for direct three-dimensional (3D) reconstruction of vascular structures. Methods. To explore the imaging performance of the system for reconstructing a vascular structure, two sets of projection images of avascular phantom, acquired over 250 projection angles with two different-sized IIs, were digitized and used for a direct 3D cone-beam reconstruction. The signal-to-noise ratio (SNR) of each reconstructed image was measured. From these measurements, image quality was accessed as a function of the number of reconstructions averaged and the different orientations, The spatial resolution limits of the system were measured from the 3D reconstructed images of a specially designed resolution phantom for different orientations and locations, Results. The measured SNRs of all direct 3D reconstruction images were reasonably good, and background noise levels measured from 3D reconstruction images were almost 30 Hounsfield units. The measured spatial resolution of the system was 0.5 line pairs per millimeter. However, spatial resolution was reduced around the edge of the II to nearly half that measured in the central area of the field of view. Conclusion. An II-based volume CT scanner can produce direct 3D reconstructions of vascular structures with good image quality for intraarterial angiography.
引用
收藏
页码:344 / 350
页数:7
相关论文
共 20 条
[1]   CAPABILITY OF FLUOROSCOPIC SYSTEMS FOR PRODUCTION OF COMPUTERIZED AXIAL TOMOGRAMS [J].
BAILY, NA ;
KELLER, RA ;
JAKOWATZ, CV ;
KAK, AC .
INVESTIGATIVE RADIOLOGY, 1976, 11 (05) :434-439
[2]  
BOONE JM, 1990, RADIOLOGY, V177, P136
[3]  
DUINKER S, 1978, OLDEFT SCI ENG, V1, P448
[4]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[5]   THE DIRECT EXAMINATION OF 3-DIMENSIONAL BONE ARCHITECTURE INVITRO BY COMPUTED-TOMOGRAPHY [J].
FELDKAMP, LA ;
GOLDSTEIN, SA ;
PARFITT, AM ;
JESION, G ;
KLEEREKOPER, M .
JOURNAL OF BONE AND MINERAL RESEARCH, 1989, 4 (01) :3-11
[6]  
HARRISON RM, 1978, BRIT J RADIOL, V59, P41
[7]   A HIGH-RESOLUTION XRII-BASED QUANTITATIVE VOLUME CT SCANNER [J].
HOLDSWORTH, DW ;
DRANGOVA, M ;
FENSTER, A .
MEDICAL PHYSICS, 1993, 20 (02) :449-462
[8]   A SIMULATOR-BASED CT SYSTEM FOR RADIOTHERAPY TREATMENT PLANNING [J].
KOTRE, CJ ;
HARRISON, RM ;
ROSS, WM .
BRITISH JOURNAL OF RADIOLOGY, 1984, 57 (679) :631-635
[9]   3-DIMENSIONAL X-RAY MICROTOMOGRAPHY FOR MEDICAL AND BIOLOGICAL APPLICATIONS [J].
MORTON, EJ ;
WEBB, S ;
BATEMAN, JE ;
CLARKE, LJ ;
SHELTON, CG .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (07) :805-820
[10]   COMPUTER-SIMULATION OF IMAGE INTENSIFIER-BASED COMPUTED-TOMOGRAPHY DETECTOR - VASCULAR APPLICATION [J].
NING, R ;
KRUGER, RA .
MEDICAL PHYSICS, 1988, 15 (02) :188-192