Label-free protein recognition using an aptamer-based impedance measurement assay

被引:151
作者
Cai, H [1 ]
Lee, TMH [1 ]
Hsing, IM [1 ]
机构
[1] Hong Kong Univ Sci & Technol, Dept Chem Engn, Kowloon, Hong Kong, Peoples R China
关键词
aptamer; thrombin; label-free protein detection; electrochemical impedance spectroscopy;
D O I
10.1016/j.snb.2005.06.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel aptamer-based biosensing assay for label-free protein detection and quantification by measuring the change in electrochemical impedance upon protein-aptamer complex formation was demonstrated. Our process starts with a self-assembly of the DNA aptamer on a microfabricated thin film gold electrode, followed by the recognition of the protein binding event via monitoring the interfacial electron transfer resistance with electrochemical impedance spectroscopy. The thrombin binding aptamer (TBA) has high binding affinity and specificity to its target protein and the impedance detection assay shows a reliable and sensitive quantification of thrombin with a detection range of four orders of magnitude and a detection limit of 0.1 nM. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:433 / 437
页数:5
相关论文
共 30 条
[1]   SELECTION OF SINGLE-STRANDED-DNA MOLECULES THAT BIND AND INHIBIT HUMAN THROMBIN [J].
BOCK, LC ;
GRIFFIN, LC ;
LATHAM, JA ;
VERMAAS, EH ;
TOOLE, JJ .
NATURE, 1992, 355 (6360) :564-566
[2]   The use of aptamers in large arrays for molecular diagnostics [J].
Brody, EN ;
Willis, MC ;
Smith, JD ;
Jayasena, S ;
Zichi, D ;
Gold, L .
MOLECULAR DIAGNOSIS, 1999, 4 (04) :381-388
[3]   Sequence-specific electrochemical recognition of multiple species using nanoparticle labels [J].
Cai, H ;
Shang, C ;
Hsing, IM .
ANALYTICA CHIMICA ACTA, 2004, 523 (01) :61-68
[4]   A DNA-based machine that can cyclically bind and release thrombin [J].
Dittmer, WU ;
Reuter, A ;
Simmel, FC .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2004, 43 (27) :3550-3553
[5]   INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS [J].
ELLINGTON, AD ;
SZOSTAK, JW .
NATURE, 1990, 346 (6287) :818-822
[6]   Molecular aptamer for real-time oncoprotein platelet-derived growth factor monitoring by fluorescence anisotropy [J].
Fang, XH ;
Cao, ZH ;
Beck, T ;
Tan, WH .
ANALYTICAL CHEMISTRY, 2001, 73 (23) :5752-5757
[7]   Detection of aptamer-protein interactions using QCM and electrochemical indicator methods [J].
Hianik, T ;
Ostatná, V ;
Zajacová, Z ;
Stoikova, E ;
Evtugyn, G .
BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2005, 15 (02) :291-295
[8]   Optical sensors based on hybrid aptamer/conjugated polymer complexes [J].
Ho, HA ;
Leclerc, M .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (05) :1384-1387
[9]   Novel electrochemical sensor system for protein using the aptamers in sandwich manner [J].
Ikebukuro, K ;
Kiyohara, C ;
Sode, K .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (10) :2168-2172
[10]   Reconciliation of the X-ray and NMR structures of the thrombin-binding aptamer d(GGTTGGTGTGGTTGG) [J].
Kelly, JA ;
Feigon, J ;
Yeates, TO .
JOURNAL OF MOLECULAR BIOLOGY, 1996, 256 (03) :417-422