In vitro activation of human leukocytes in response to contact with synthetic hernia meshes

被引:17
作者
Bryan, N. [1 ]
Ahswin, H. [3 ]
Smart, N. J. [2 ]
Bayon, Y. [3 ]
Hunt, J. A. [1 ]
机构
[1] Univ Liverpool, Inst Ageing & Chron Dis, UKBioTEC, UKCTE, Liverpool L69 3GA, Merseyside, England
[2] Royal Devon & Exeter Hosp, Exeter Colorectal Unit, Exeter EX2 5DW, Devon, England
[3] Covidien Sofradim Prod, F-01600 Trevoux, France
基金
英国医学研究理事会;
关键词
Acute inflammation; Chronic pain; Neutrophil; Chemiluminescence; In vitro; NEUTROPHIL ACTIVATION; INGUINAL-HERNIA; CHRONIC PAIN; REPAIR; INFLAMMATION; MACROPHAGES; CELLS;
D O I
10.1016/j.clinbiochem.2012.02.026
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
100118 [医学信息学]; 100208 [临床检验诊断学];
摘要
Objectives: Evaluation of an in vitro chemiluminescent screen to predict leukocyte ROS in response to surgical materials. Design and methods: 6 surgical meshes; manufacture and knitting variations of polypropylene (PP), polyester terephtalate (PET) and polyglycolic acid (PGA) trialled healthy human blood (n = 5). Materials and blood were incubated with pholasin. Pholasin emits photons in the presence of reactive oxygen species; secreted by activated leukocytes. Results: Multifilament-PGA mesh stimulated the greatest ROS response from blood derived human leukocytes. Multifilament-PET light weight and multifilament-PP meshes stimulated similar levels of ROS production which were greater than monofilament-PP light, monofilament-PP and monofilament-PET light meshes. Data demonstrated statistical variations in trans-donor response to the materials. Conclusions: An in vitro chemiluminescent assay can be used to assess leukocyte respiratory burst response to biomaterials. PGA mesh elicited the greatest ROS response. PP and PET monofilament meshes induce less ROS than multifilament equivalents. In vitro results correlate with previously published clinical responses to these materials. (C) 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:672 / 676
页数:5
相关论文
共 38 条
[1]
Adamson R, 2009, J Wound Care, V18, P349
[2]
Inflammatory response to implants [J].
Anderson, J.M. .
ASAIO Transactions, 1988, 34 (02) :101-107
[3]
The structure of a biomaterial rather than its chemical composition modulates the repair process at the peritoneal level [J].
Bellón, JM ;
Jurado, F ;
García-Honduvilla, N ;
López, R ;
Carrera-San Martín, A ;
Buján, J .
AMERICAN JOURNAL OF SURGERY, 2002, 184 (02) :154-159
[4]
Neutrophil activation by adhesion: Mechanisms and pathophysiological implications [J].
Berton, G ;
Yan, SR ;
Funagalli, L ;
Lowell, CA .
INTERNATIONAL JOURNAL OF CLINICAL & LABORATORY RESEARCH, 1996, 26 (03) :160-177
[5]
Tissue integration and tolerance to meshes used in gynecologic surgery: An experimental study [J].
Boulanger, Loic ;
Boukerrou, Malik ;
Lambaudie, Eric ;
Defossez, Andre ;
Cosson, Michel .
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2006, 125 (01) :103-108
[6]
Hernia repair: the search for ideal meshes [J].
Bringman, S. ;
Conze, J. ;
Cuccurullo, D. ;
Deprest, J. ;
Junge, K. ;
Klosterhalfen, B. ;
Parra-Davila, E. ;
Ramshaw, B. ;
Schumpelick, V. .
HERNIA, 2010, 14 (01) :81-87
[7]
Butterfield TA, 2006, J ATHL TRAINING, V41, P457
[8]
Inguinal hernia repair: The choice of prosthesis outweighs that of technique [J].
Champault G. ;
Bernard C. ;
Rizk N. ;
Polliand C. .
Hernia, 2007, 11 (2) :125-128
[9]
Stress and wound healing [J].
Christian, Lisa M. ;
Graham, Jennifer E. ;
Padgett, David A. ;
Glaser, Ronald ;
Kiecolt-Glaser, Janice K. .
NEUROIMMUNOMODULATION, 2006, 13 (5-6) :337-346
[10]
Polypropylene as a reinforcement in pelvic surgery is not inert: comparative analysis of 100 explants [J].
Clave, Arnaud ;
Yahi, Hannah ;
Hammou, Jean-Claude ;
Montanari, Suzelei ;
Gounon, Pierre ;
Clave, Henri .