A New Tourniquet System that Determines Pressures in Synchrony With Systolic Blood Pressure in Total Knee Arthroplasty

被引:16
作者
Ishii, Yoshinori [1 ]
Noguchi, Hideo [1 ]
Matsuda, Yoshikazu [1 ]
Takeda, Mitsuhiro [1 ]
Higashihara, To-ichi [2 ]
机构
[1] Ishii Orthopaed & Rehabil Clin, Saitama 3610037, Japan
[2] Mizuho Ika CC, Tokyo, Japan
关键词
tourniquet; systolic blood pressure; total knee arthroplasty;
D O I
10.1016/j.arth.2007.08.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study reports the comparison of the clinical use of a new tourniquet system for total knee arthroplasty that can determine its pressure in synchrony with systolic blood pressure (SBP) with the conventional that keeps the initial setting pressure. We prospectively applied the additional pressure of 100 mm Hg based on the SBP recorded before skin incision to consecutive 72 procedures (conventional, initial 36; new, following 36). Six knees with the conventional and none of 5 with the new showed oozing blood in surgical field after sharp rise in SBP. Based on no statistically significant differences of the perioperative blood loss Without ally tourniquet-related postoperative complications in both groups, the new system seemed to be a practical device especially for controlling a bloodless surgical field.
引用
收藏
页码:1050 / 1056
页数:7
相关论文
共 36 条
[1]   EFFECTS OF TOURNIQUET DURING TOTAL KNEE ARTHROPLASTY - A PROSPECTIVE RANDOMIZED STUDY [J].
ABDELSALAM, A ;
EYRES, KS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (02) :250-253
[2]   Postoperative drainage of knee arthroplasty is not necessary - A randomized study of 90 patients [J].
Adalberth, G ;
Bystrom, S ;
Kolstad, K ;
Mallmin, H ;
Milbrink, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (05) :475-478
[3]  
Barwell NJ, 1997, J BONE JOINT SURG BR, V79B, P265
[4]   Blood loss in sequential bilateral total knee arthroplasty [J].
Bould, M ;
Freeman, BJC ;
Pullyblank, A ;
Newman, JH .
JOURNAL OF ARTHROPLASTY, 1998, 13 (01) :77-79
[5]  
BURKART BC, 1994, CLIN ORTHOP RELAT R, V299, P147
[6]   Small-dose propofol sedation attenuates the formation of reactive oxygen species in tourniquet-induced ischemia-reperfusion injury under spinal anesthesia [J].
Cheng, YJ ;
Wang, YP ;
Chien, CT ;
Chen, CF .
ANESTHESIA AND ANALGESIA, 2002, 94 (06) :1617-1620
[7]  
CUSHNER FD, 1991, CLIN ORTHOP RELAT R, V269, P98
[8]  
GRAHAM B, 1993, CLIN ORTHOP RELAT R, P257
[9]   ESTIMATING ALLOWABLE BLOOD-LOSS - CORRECTED FOR DILUTION [J].
GROSS, JB .
ANESTHESIOLOGY, 1983, 58 (03) :277-280
[10]   Tranexamic acid radically decreases blood loss and transfusions associated with total knee arthroplasty [J].
Hiippala, ST ;
Strid, LJ ;
Wennerstrand, MI ;
Arvela, JVV ;
Niemela, HM ;
Mantyla, SK ;
Kuisma, RP ;
Ylinen, JE .
ANESTHESIA AND ANALGESIA, 1997, 84 (04) :839-844