Monitoring the removal of carbonate from alkali metal hydroxide solutions using gas diffusion flow injection

被引:4
作者
Wei, YL [1 ]
Oshima, M [1 ]
Motomizu, S [1 ]
机构
[1] Okayama Univ, Fac Sci, Dept Chem, Okayama 7008530, Japan
关键词
D O I
10.1039/b109771g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring the removal of carbonate from alkali metal hydroxide (MOH, M=K, Na) solutions with calcium oxide (CaO) was studied using a newly developed method for the determination of trace amounts of total carbonate (TC) in alkaline solutions based on a flow injection (FI) technique coupled with a gas diffusion system. The optimized conditions of the FI system were as follows: the flow rate of each carrier, reaction solution (H2SO4) and receptor solution (Cresol Red, pH 8.9) was 0.25 ml min(-1), the sample size was 0.1 ml and the concentration of H2SO4 in the reaction solution was 0.09 M. The limit of detection of TC by the proposed method was 4x10(-7) M. The removal efficiency of carbonate was affected by the amount of CaO added, the shaking time of the solutions and the concentration of MOH. For 1 M NaOH and KOH solution, the removal efficiency of carbonate was about 99% and the concentration of residual carbonate was 4x10(-5) and 1.2x10(-4) M, respectively, when the amount of CaO added was 2 g l(-1) and the shaking time was 16 h.
引用
收藏
页码:424 / 427
页数:4
相关论文
共 13 条
[1]   CONTINUOUS-FLOW METHOD FOR THE DETERMINATION OF TOTAL INORGANIC CARBONATE IN WATER [J].
AOKI, T ;
FUJIMARU, Y ;
OKA, Y ;
FUJIE, K .
ANALYTICA CHIMICA ACTA, 1993, 284 (01) :167-171
[2]   The solubility of alkali-sulphate in alkali-containing solutions at 25(o) - Gypsum in this solution of alkali-sulphate and free alkaline [J].
D'Ans, J ;
Schreiner, O .
ZEITSCHRIFT FUR ANORGANISCHE CHEMIE, 1910, 67 (04) :437-441
[3]  
Higuchi K, 1999, BUNSEKI KAGAKU, V48, P253
[4]   COMPARISON OF PHOTOMETRY AND CONDUCTOMETRY FOR THE DETERMINATION OF TOTAL CARBONATE BY GAS PERMEATION FLOW-INJECTION ANALYSIS [J].
KUBAN, V ;
DASGUPTA, PK .
TALANTA, 1993, 40 (06) :831-840
[5]  
KUWAKI T, 1987, BUNSEKI KAGAKU, V36, pT132
[6]   GAS-DIFFUSION UNIT WITH TUBULAR MICROPOROUS POLY(TETRAFLUOROETHYLENE) MEMBRANE FOR FLOW-INJECTION DETERMINATION OF CARBON-DIOXIDE [J].
MOTOMIZU, S ;
TOEI, K ;
KUWAKI, T ;
OSHIMA, M .
ANALYTICAL CHEMISTRY, 1987, 59 (24) :2930-2932
[7]   Highly sensitive determination method for total carbonate in water samples by flow injection analysis coupled with gas-diffusion separation [J].
Oshima, M ;
Wei, YL ;
Yamamoto, M ;
Tanaka, H ;
Takayanagi, T ;
Motomizu, S .
ANALYTICAL SCIENCES, 2001, 17 (11) :1285-1290
[8]   Structure of aqueous sodium aluminate solutions: A solution X-ray diffraction study [J].
Radnai, T ;
May, PM ;
Hefter, GT ;
Sipos, P .
JOURNAL OF PHYSICAL CHEMISTRY A, 1998, 102 (40) :7841-7850
[9]  
SANADA M, 1993, BUNSEKI KAGAKU, V42, pT123
[10]   Carbonate removal from concentrated hydroxide solutions [J].
Sipos, P ;
May, PM ;
Hefter, GT .
ANALYST, 2000, 125 (05) :955-958