Thoracic aortic dissection and aneurysm: Evaluation with nonenhanced true FISP MR angiography in less than 4 minutes

被引:83
作者
Pereles, FS
McCarthy, RM
Baskaran, V
Carr, JC
Kapoor, V
Krupinski, EA
Finn, JP
机构
[1] Northwestern Univ, Sch Med, Dept Radiol, Chicago, IL 60611 USA
[2] Univ Arizona, Hlth Sci Ctr, Tucson, AZ USA
关键词
aorta; dissection; aneurysm; aortic; magnetic resonance (MR); cine study; vascular studies;
D O I
10.1148/radiol.2231010966
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Comprehensive aortic magnetic resonance (MR) examinations currently include multiple nonenhanced and contrast material-enhanced sequences. The authors hypothesized that the nonenhanced true fast imaging with steady-state precession (FISP) portion alone of their comprehensive imaging protocol would be adequate to confidently confirm or exclude dissection or aneurysm of the aorta. In a retrospective review of 29 comprehensive thoracic aortic MR examinations, nonenhanced true FISP MR imaging alone was 100% accurate for determining the presence or absence of dissection or aneurysm. © RSNA, 2002.
引用
收藏
页码:270 / 274
页数:5
相关论文
共 9 条
[1]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[2]  
Deimling M., 1994, PROC 2 ANN M SMR SAN, P495
[3]   RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD [J].
DORFMAN, DD ;
BERBAUM, KS ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (09) :723-731
[4]  
FINN JP, IN PRESS RADIOLOGY
[5]   3D time-resolved contrast-enhanced MR DSA: Advantages and tradeoffs [J].
Mistretta, CA ;
Grist, TM ;
Korosec, FR ;
Frayne, R ;
Peters, DC ;
Mazaheri, Y ;
Carroll, TJ .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (04) :571-581
[6]   THE DIAGNOSIS OF THORACIC AORTIC DISSECTION BY NONINVASIVE IMAGING PROCEDURES [J].
NIENABER, CA ;
VONKODOLITSCH, Y ;
NICOLAS, V ;
SIGLOW, V ;
PIEPHO, A ;
BROCKHOFF, C ;
KOSCHYK, DH ;
SPIELMANN, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 328 (01) :1-9
[7]   Usefulness of segmented TrueFISP cardiac pulse sequence in evaluation of congenital and acquired adult cardiac abnormalities [J].
Pereles, FS ;
Kapoor, V ;
Carr, JC ;
Simonetti, OP ;
Krupinski, EA ;
Baskaran, V ;
Finn, JP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (05) :1155-1160
[8]  
PRINCE MR, 1999, 3D CONTRAST MR ANGIO, P53
[9]   Clinical evaluation of aortic diseases using nonenhanced MRA with ECG-triggered 3D half-fourier FSE [J].
Urata, J ;
Miyazaki, M ;
Wada, H ;
Nakaura, T ;
Yamashita, Y ;
Takahashi, M .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (02) :113-119