Clinical evaluation of aortic diseases using nonenhanced MRA with ECG-triggered 3D half-fourier FSE

被引:47
作者
Urata, J [1 ]
Miyazaki, M [1 ]
Wada, H [1 ]
Nakaura, T [1 ]
Yamashita, Y [1 ]
Takahashi, M [1 ]
机构
[1] Saiseikai Kumamoto Hosp, Diagnost Imaging Ctr, Kumamoto, Japan
关键词
aortic disease; nonenhanced MRA; fresh-blood imaging (FBI); electrocardiographic (ECG) triggering; ECG-prep scan;
D O I
10.1002/jmri.1160
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The efficacy of the nonenhanced magnetic resonance angiography (MRA) technique known as fresh-blood Imaging (FBI), using electrocardiograph (ECG)-triggered 3D half-Fourier fast spin-echo (FSE), was evaluated for the detection and characterization of aortic diseases. Seventy-five consecutive patients with aortic disease underwent the FBI examination on a 1.5-T clinical imager. The results showed that the FBI technique permits clear visualization of aortic diseases, and the vessel branches and their relationship, which provides valuable information. Therefore, the nonenhanced FBI technique is appropriate to use for screening purposes. (C) 2001 Wlley-Liss, Inc.
引用
收藏
页码:113 / 119
页数:7
相关论文
共 13 条
[1]   Ultrafast contrast-enhanced three-dimensional MR angiography: State of the art [J].
Alley, MT ;
Shifrin, RY ;
Pelc, NJ ;
Herfkens, RJ .
RADIOGRAPHICS, 1998, 18 (02) :273-285
[2]   MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DUMOULIN, CL ;
HART, HR .
RADIOLOGY, 1986, 161 (03) :717-720
[3]   RAPID SCAN MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DUMOULIN, CL ;
SOUZA, SP ;
HART, HR .
MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (03) :238-245
[4]   PROJECTION ARTERIOGRAPHY AND VENOGRAPHY - INITIAL CLINICAL-RESULTS WITH MR [J].
EDELMAN, RR ;
WENTZ, KU ;
MATTLE, H ;
ZHAO, B ;
LIU, C ;
KIM, D ;
LAUB, G .
RADIOLOGY, 1989, 172 (02) :351-357
[5]   Thoracic duct: Visualization at nonenhanced MR lymphography - Initial experience [J].
Hayashi, S ;
Miyazaki, M .
RADIOLOGY, 1999, 212 (02) :598-600
[6]   Thoracic MR aortography: Imaging techniques and strategies [J].
Ho, VB ;
Prince, MR .
RADIOGRAPHICS, 1998, 18 (02) :287-309
[7]  
KITA M, 2000, P 8 ANN M ISMRM DENV, P692
[8]   MR ANGIOGRAPHY WITH GRADIENT MOTION REFOCUSING [J].
LAUB, GA ;
KAISER, WA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (03) :377-382
[9]   A novel MR angiography technique: SPEED acquisition using half-Fourier RARE [J].
Miyazaki, M ;
Ichinose, N ;
Sugiura, S ;
Kassai, Y ;
Kanazawa, H ;
Machida, Y .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (02) :505-507
[10]  
Miyazaki M, 2000, J MAGN RESON IMAGING, V12, P776, DOI 10.1002/1522-2586(200011)12:5<776::AID-JMRI17>3.0.CO