Thoracic MR aortography: Imaging techniques and strategies

被引:47
作者
Ho, VB
Prince, MR
机构
[1] Uniformed Serv Univ Hlth Sci, Dept Radiol & Nucl Med, Bethesda, MD 20814 USA
[2] Madigan Army Med Ctr, Dept Clin Invest, Tacoma, WA 98431 USA
[3] Madigan Army Med Ctr, Dept Radiol, Tacoma, WA 98431 USA
[4] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
aneurism; aortic; aorta; abnormalities; dissection; gadolinium; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiographics.18.2.9536478
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) angiography is a promising technique for thoracic aortography that complements electrocardiographically gated T1-weighted spin-echo imaging and cine MR imaging, Axial and left anterior oblique T1-weighted spin-echo images are well suited to measurement of aortic dimensions and evaluation of aortic aneurysms, Sagittal and coronal spin-echo images are helpful in evaluation of vascular rings and aortic dissection, Cine gradient-echo and cine phase-contrast imaging allow dynamic evaluation of aortic and valvular flow. Cine phase-contrast imaging also enables noninvasive quantification of blood flow, Capable of being performed during a single breath hold, 3D gadolinium-enhanced MR angiography provides high-resolution 3D data that can be readily used for projection angiography and multiplanar reformation. This technique enables further demonstration of subtle pathologic conditions. Three-dimensional gadolinium-enhanced MR angiography allows more comprehensive and efficient evaluation of the thoracic aorta.
引用
收藏
页码:287 / 309
页数:23
相关论文
共 27 条
[1]   AORTIC DISSECTION - MAGNETIC-RESONANCE IMAGING [J].
AMPARO, EG ;
HIGGINS, CB ;
HRICAK, H ;
SOLLITTO, R .
RADIOLOGY, 1985, 155 (02) :399-406
[2]   VASCULAR RINGS - MR IMAGING [J].
BISSET, GS ;
STRIFE, JL ;
KIRKS, DR ;
BAILEY, WW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (02) :251-256
[3]   QUANTITATION OF ANTEGRADE AND RETROGRADE BLOOD-FLOW IN THE HUMAN AORTA BY MAGNETIC-RESONANCE VELOCITY MAPPING [J].
BOGREN, HG ;
KLIPSTEIN, RH ;
FIRMIN, DN ;
MOHIADDIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 117 (06) :1214-1222
[4]   CINE MR IMAGING IN AORTIC-STENOSIS [J].
DEROOS, A ;
REICHEK, N ;
AXEL, L ;
KRESSEL, HY .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (03) :421-425
[5]   CINE GRADIENT-ECHO MR-IMAGING IN THE EVALUATION OF CARDIOVASCULAR-DISEASES [J].
DIDIER, D ;
RATIB, O ;
FRIEDLI, B ;
OBERHAENSLI, I ;
CHATELAIN, P ;
FAIDUTTI, B ;
RUTISHAUSER, W ;
TERRIER, F .
RADIOGRAPHICS, 1993, 13 (03) :561-573
[6]   SPATIAL PRESATURATION - A METHOD FOR SUPPRESSING FLOW ARTIFACTS AND IMPROVING DEPICTION OF VASCULAR ANATOMY IN MR IMAGING [J].
FELMLEE, JP ;
EHMAN, RL .
RADIOLOGY, 1987, 164 (02) :559-564
[7]   THORACIC AORTIC DISSECTIONS - MAGNETIC-RESONANCE IMAGING [J].
GEISINGER, MA ;
RISIUS, B ;
ODONNELL, JA ;
ZELCH, MG ;
MOODIE, DS ;
GRAOR, RA ;
GEORGE, CR .
RADIOLOGY, 1985, 155 (02) :407-412
[8]   THE THORACIC AORTA STUDIED BY MR IMAGING [J].
GLAZER, HS ;
GUTIERREZ, FR ;
LEVITT, RG ;
LEE, JKT ;
MURPHY, WA .
RADIOLOGY, 1985, 157 (01) :149-155
[9]  
GOMES AS, 1989, RADIOL CLIN N AM, V27, P1171
[10]   MR-IMAGING OF THE THORACIC AORTA - COMPARISON OF SPIN-ECHO, ANGIOGRAPHIC, AND BREATH-HOLD TECHNIQUES [J].
HARTNELL, GG ;
FINN, JP ;
ZENNI, M ;
COHEN, MC ;
DUPUY, DE ;
WHEELER, HG ;
LONGMAID, HE .
RADIOLOGY, 1994, 191 (03) :697-704