Affinity-selected filamentous bacteriophage as a probe for acoustic wave biodetectors of Salmonella typhimurium

被引:118
作者
Olsen, EV
Sorokulova, IB
Petrenko, VA
Chen, IH
Barbaree, JM
Vodyanoy, VJ
机构
[1] Auburn Univ, Coll Vet Med, Dept Anat Physiol & Pharmacol, Auburn, AL 36849 USA
[2] Auburn Univ, Dept Biol Sci, Auburn, AL 36849 USA
[3] Auburn Univ, Coll Vet Med, Dept Pathobiol, Auburn, AL 36849 USA
关键词
biosensor; filamentous bacteriophage; phage display; piezoelectric; quartz crystal microbalance; Salmonella typhimurium;
D O I
10.1016/j.bios.2005.06.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Proof-in-concept biosensors were prepared for the rapid detection of Salmonella typhimurium in solution, based on affinity-selected filamentous phage prepared as probes physically adsorbed to piezoelectric transducers. Quantitative deposition studies indicated that approximate to 3 x 10(10) phage particles/cm(2) could be irreversibly adsorbed for I h at room temperature to prepare working biosensors. The quality of phage deposition was monitored by fluorescent microscopy. Specific-bacterial binding resulted in resonance frequency changes of prepared sensors, which were evaluated using linear regression analysis. Sensors possessed a rapid response time of < 180 s, had a low-detection limit of 10(2) cells/ml and were linear over a range of 10(1)-10(7) cells/ml with a sensitivity of 10.9 Hz per order of magnitude of S. typhimurium concentration. Viscosity effects due to increasing bacterial concentration and non-specific binding were not significant to the piezoelectric platform as confirmed by dose-response analysis. Phage-bacterial binding was confirmed by fluorescence and scanning electron microscopy. Overall, phage may constitute effective bioreceptors for use with analytical platforms for detecting and monitoring bacterial agents, including use in food products and possibly biological warfare applications. (c) 2005 Published by Elsevier B.V.
引用
收藏
页码:1434 / 1442
页数:9
相关论文
共 20 条
[1]   Market analysis of biosensors for food safety [J].
Alocilja, EC ;
Radke, SM .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :841-846
[2]  
*CDCP, 2005, PREL FOODN DAT INC I
[4]   Thickness shear mode resonators ("mass-sensitive devices") in bioanalysis [J].
Kaspar, M ;
Stadler, H ;
Weiss, T ;
Ziegler, C .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (6-7) :602-610
[5]  
Khan AS, 2001, PUBLIC HEALTH REP, V116, P3, DOI 10.1093/phr/116.1.3
[6]  
*MAXT INC, 2003, RQCM OP SEV MAN, P1
[7]   Specific and selective biosensor for Salmonella and its detection in the environment [J].
Olsen, EV ;
Pathirana, ST ;
Samoylov, AM ;
Barbaree, JM ;
Chin, BA ;
Neely, WC ;
Vodyanoy, V .
JOURNAL OF MICROBIOLOGICAL METHODS, 2003, 53 (02) :273-285
[8]   Effects of virion and salt concentrations on the Raman signatures of filamentous phages fd, Pf1, Pf3, and PH75 [J].
Overman, SA ;
Kristensen, DM ;
Bondre, P ;
Hewitt, B ;
Thomas, GJ .
BIOCHEMISTRY, 2004, 43 (41) :13129-13136
[9]   Rapid and sensitive biosensor for Salmonella [J].
Pathirana, ST ;
Barbaree, J ;
Chin, BA ;
Hartell, MG ;
Neely, WC ;
Vodyanoy, V .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4) :135-141
[10]   Phages from landscape libraries as substitute antibodies [J].
Petrenko, VA ;
Smith, GP .
PROTEIN ENGINEERING, 2000, 13 (08) :589-592