Decomplexing biofluids using microchip based acoustophoresis

被引:53
作者
Augustsson, Per [1 ]
Persson, Jonas [1 ]
Ekstrom, Simon [1 ]
Ohlin, Mats [1 ]
Laurell, Thomas [1 ]
机构
[1] Lund Univ, Dept Elect Measurements, Div Nanobiotechnol, S-22100 Lund, Sweden
基金
瑞典研究理事会;
关键词
MASS-SPECTROMETRY; AFFINITY-CHROMATOGRAPHY; MICROFLUIDIC CHANNELS; SAMPLE PREPARATION; STANDING WAVES; PHAGE DISPLAY; TOF MS; ULTRASOUND; PARTICLE; MICRODIALYSIS;
D O I
10.1039/b811027a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Highly efficient washing and extraction of microbeads to decomplex analytes ranging from small peptides to large viruses was realised in a microscaled continuous flow format. The bead washing principle reported herein is based on acoustophoresis, i.e. the primary acoustic radiation force in an ultrasonic standing wave and laminar flow properties are utilised to translate bioanalytes trapped on functionalised microbeads from one carrier fluid to another. The carry-over of non-specific material ranges from 1 to 50 ppm relative to input levels depending on application, making acoustophoresis suitable for extraction of rare species from complex environments. Selective extraction of a phosphopeptide relative to its unphosphorylated counterpart is demonstrated using metal oxide affinity capture (MOAC) beads and MALDI-TOF MS readout. Acoustophoresis of microbeads activated with specific binders could be used to capture phage viral particles. The efficiency of the acoustophoretic washing principle was demonstrated by an unspecific phage cross contamination level of only 10(-6) of that in the input bead/phage mixture. The continuous flow format makes acoustophoretic washing flexible regarding sample volume and also allows for easy integration into a sequence of particle handling and analytical unit operations.
引用
收藏
页码:810 / 818
页数:9
相关论文
共 35 条
[1]   Comparison of different depletion strategies for improved resolution in proteomic analysis of human serum samples [J].
Björhall, K ;
Miliotis, T ;
Davidsson, P .
PROTEOMICS, 2005, 5 (01) :307-317
[2]   Polymeric integrated selective enrichment target (ISET) for solid-phase-based sample preparation in MALDI-TOF MS [J].
Ekstrom, Simon ;
Wallman, Lars ;
Helldin, Goran ;
Nilsson, Johan ;
Marko-Varga, Gyorgy ;
Laurell, Thomas .
JOURNAL OF MASS SPECTROMETRY, 2007, 42 (11) :1445-1452
[3]  
Gorkov L.P., 1962, Sov. Phys. Dokl, V6, P773
[4]  
GOULD RK, 1973, P S FIN AMPL WAV EFF, P262
[5]   Continuous cell washing and mixing driven by an ultrasound standing wave within a microfluidic channel [J].
Hawkes, JJ ;
Barber, RW ;
Emerson, DR ;
Coakley, WT .
LAB ON A CHIP, 2004, 4 (05) :446-452
[6]   Force field particle filter, combining ultrasound standing waves and laminar flow [J].
Hawkes, JJ ;
Coakley, WT .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 75 (03) :213-222
[7]   One-step fractionation of complex proteomes enables detection of low abundant analytes using antibody-based microarrays [J].
Ingvarsson, J ;
Lindstedt, M ;
Borrebaeck, CAK ;
Wingren, C .
JOURNAL OF PROTEOME RESEARCH, 2006, 5 (01) :170-176
[8]  
Kussmann M, 1997, J MASS SPECTROM, V32, P593
[9]  
Lantto J, 2002, EUR J IMMUNOL, V32, P1659, DOI 10.1002/1521-4141(200206)32:6<1659::AID-IMMU1659>3.0.CO
[10]  
2-9