PET quantitation and imaging of the non-pure positronemitting iodine isotope 124I

被引:71
作者
Herzog, H
Tellmann, L
Qaim, SM
Spellerberg, S
Schmid, A
Coenen, HH
机构
[1] Forschungszentrum Julich, Inst Med, D-52425 Julich, Germany
[2] Forschungszentrum Julich, Inst Nucl Chem, D-52425 Julich, Germany
关键词
I-124; PET imaging; PET quantitation;
D O I
10.1016/S0969-8043(01)00283-4
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A series of PET studies using phantoms is presented to characterize the imaging and quantitative performance of the positron-emitting iodine isotope I-124. Measurements were performed on the 2D-PET scanner GE 4096 + as well as on the Siemens PET scanner HR+ operated in both 2D and 3D modes. No specific correction was applied for the gamma-rays emitted together with the positrons. As compared to F-18, in studies with I-124 there is a small loss of image resolution and contrast, and an increase in background. The quantitative results varied between different scanners and various acquisition as well as reconstruction modes, with an average relative difference of -6 +/- 13% (mean+/-SD) in respect of the phantom radioactivity as measured with gamma-ray spectroscopy. We conclude that quantitation of a radiopharmaceutical labelled with I-124 is feasible and may be improved by the development of specific corrections. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:673 / 679
页数:7
相关论文
共 16 条
[1]   Excitation functions of 124Te(d,xn)124,125I reactions from threshold up to 14 MeV:: comparative evaluation of nuclear routes for the production of 124I [J].
Bastian, T ;
Coenen, HH ;
Qaim, SM .
APPLIED RADIATION AND ISOTOPES, 2001, 55 (03) :303-308
[2]   CORRECTION FOR SCATTERED RADIATION IN A RING DETECTOR POSITRON CAMERA BY INTEGRAL TRANSFORMATION OF THE PROJECTIONS [J].
BERGSTROM, M ;
ERIKSSON, L ;
BOHM, C ;
BLOMQVIST, G ;
LITTON, J .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (01) :42-50
[3]  
Brix G, 1997, J NUCL MED, V38, P1614
[4]  
Carnochan P, 1994, J Nucl Biol Med, V38, P96
[5]   N.C.A. RADIOSYNTHESIS OF [I-123,I-124]BETA-CIT, PLASMA ANALYSIS AND PHARMACOKINETIC STUDIES WITH SPECT AND PET [J].
COENEN, HH ;
DUTSCHKA, K ;
MULLER, SP ;
GEWORSKI, L ;
FARAHATI, J ;
REINERS, C .
NUCLEAR MEDICINE AND BIOLOGY, 1995, 22 (08) :977-984
[6]   Exact and approximate rebinning algorithms for 3-D PET data [J].
Defrise, M ;
Kinahan, PE ;
Townsend, DW ;
Michel, C ;
Sibomana, M ;
Newport, DF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :145-158
[7]   3-DIMENSIONAL IMAGE-RECONSTRUCTION FROM COMPLETE PROJECTIONS [J].
DEFRISE, M ;
TOWNSEND, DW ;
CLACK, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (05) :573-587
[8]  
ICRP, 1983, ANN ICRP, V38
[9]   PERFORMANCE-CHARACTERISTICS OF AN 8-RING WHOLE-BODY PET SCANNER [J].
KOPS, ER ;
HERZOG, H ;
SCHMID, A ;
HOLTE, S ;
FEINENDEGEN, LE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (03) :437-445
[10]  
LANGEN KJ, 1990, J NUCL MED, V31, P281