Comparison between two amplification sets for molecular diagnosis of toxoplasmosis by real-time PCR

被引:98
作者
Cassaing, S
Bessières, MH
Berry, A
Berrebi, A
Fabre, R
Magnaval, JF
机构
[1] CHU Rangueil, Serv Parasitol Mycol, F-31059 Toulouse, France
[2] Hop Paule de Viguier, Serv Gynecol Obtetri, Toulouse, France
关键词
D O I
10.1128/JCM.44.3.720-724.2006
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
PCR is now commonly applied to the diagnosis of toxoplasmosis. Although several methods are available, comparative studies are few, making it difficult to compare the performance of each technique. We compared the sensitivities of two real-time PCR assays through a prospective study on fetuses, neonates, and immuno-compromised patients and on the ocular diagnosis of toxoplasmosis. The first system targeted the widely used 131 gene (GenBank accession number AF179871) while the second (RE) targeted a more recently described sequence repeated roughly 200 to 300 times (GenBank accession number AF146527). We demonstrated that molecular diagnosis requires the duplication of PCR assays, especially with the B1 system, as only one PCR was positive in 33.3% of cases. Our study showed that the RE,target was more sensitive for all biological samples (amniotic fluid, placenta, aqueous humor, whole blood, and cerebrospinal and bronchoalveolar fluids) and significantly improved the performance of the diagnosis of toxoplasmosis. Taking into consideration all clinical samples, the mean gain in the crossing point value was 4.2 +/- 1.7 cycles and was even more significant for amniotic fluid (5.8 +/- 1.7 cycles).
引用
收藏
页码:720 / 724
页数:5
相关论文
共 26 条
[11]  
85::AID-PD18&gt
[12]  
3.0.CO
[13]  
2-1
[14]  
DESMONTS G, 1974, ARCH FR PEDIATR, V31, P157
[15]   Preliminary evaluation of one conventional nested and two real-time PCR assays for the detection of Toxoplasma gondii in immunocompromised patients [J].
Hierl, T ;
Reischl, U ;
Lang, P ;
Hebart, H ;
Stark, M ;
Kyme, P ;
Autenrieth, IB .
JOURNAL OF MEDICAL MICROBIOLOGY, 2004, 53 (07) :629-632
[16]   PRENATAL-DIAGNOSIS OF CONGENITAL TOXOPLASMOSIS WITH A POLYMERASE-CHAIN-REACTION TEST ON AMNIOTIC-FLUID [J].
HOHLFELD, P ;
DAFFOS, F ;
COSTA, JM ;
THULLIEZ, P ;
FORESTIER, F ;
VIDAUD, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (11) :695-699
[17]   Identification of a 200-to 300-fold repetitive 529 bp DNA fragment in Toxoplasma gondii, and its use for diagnostic and quantitative PCR [J].
Homan, WL ;
Vercammen, M ;
De Braekeleer, J ;
Verschueren, H .
INTERNATIONAL JOURNAL FOR PARASITOLOGY, 2000, 30 (01) :69-75
[18]  
Janitschke Klaus, 2003, Clin Lab, V49, P239
[19]  
JONES CD, 1999, INVESTIG OPHTHALMOL, V41, P634
[20]   Real-time PCR for quantitative detection of Toxoplasma gondii [J].
Lin, MH ;
Chen, TC ;
Kuo, TT ;
Tseng, CC ;
Tseng, CP .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (11) :4121-4125