Status of TAMA300

被引:137
作者
Takahashi, R [1 ]
机构
[1] Natl Astron Observ, Mitaka, Tokyo 1818588, Japan
关键词
D O I
10.1088/0264-9381/21/5/004
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The project of a laser interferometer gravitational wave detector TAMA300 is in progress. Stable operation of the power-recycled Fabry-Perot Michelson interferometer with improved sensitivity was established. The eighth data-taking run was held as an international full coincidence run with the Laser Interferometer Gravitational Wave Observatory (LIGO). We achieved an observation time of more than 1000 h with a duty cycle of more than 80%. This run can be compared with the previous run without power recycling for stability. The alignment control. system was essential to keep the condition of the interferometer optimum not only for test-mass mirrors but also for a recycling mirror.
引用
收藏
页码:S403 / S408
页数:6
相关论文
共 17 条
[1]   LIGO - THE LASER-INTERFEROMETER-GRAVITATIONAL-WAVE-OBSERVATORY [J].
ABRAMOVICI, A ;
ALTHOUSE, WE ;
DREVER, RWP ;
GURSEL, Y ;
KAWAMURA, S ;
RAAB, FJ ;
SHOEMAKER, D ;
SIEVERS, L ;
SPERO, RE ;
THORNE, KS ;
VOGT, RE ;
WEISS, R ;
WHITCOMB, SE ;
ZUCKER, ME .
SCIENCE, 1992, 256 (5055) :325-333
[2]   Current status of TAMA [J].
Ando, M .
CLASSICAL AND QUANTUM GRAVITY, 2002, 19 (07) :1409-1419
[3]   Stable operation of a 300-m laser interferometer with sufficient sensitivity to detect gravitational-wave events within our galaxy [J].
Ando, M ;
Arai, K ;
Takahashi, R ;
Heinzel, G ;
Kawamura, S ;
Tatsumi, D ;
Kanda, N ;
Tagoshi, H ;
Araya, A ;
Asada, H ;
Aso, Y ;
Barton, MA ;
Fujimoto, MK ;
Fukushima, M ;
Futamase, T ;
Hayama, K ;
Horikoshi, G ;
Ishizuka, H ;
Kamikubota, N ;
Kawabe, K ;
Kawashima, N ;
Kobayashi, Y ;
Kojima, Y ;
Kondo, K ;
Kozai, Y ;
Kuroda, K ;
Matsuda, N ;
Mio, N ;
Miura, K ;
Miyakawa, O ;
Miyama, SM ;
Miyoki, S ;
Moriwaki, S ;
Musha, M ;
Nagano, S ;
Nakagawa, K ;
Nakamura, T ;
Nakao, K ;
Numata, K ;
Ogawa, Y ;
Ohashi, M ;
Ohishi, N ;
Okutomi, S ;
Oohara, K ;
Otsuka, S ;
Saito, Y ;
Sasaki, M ;
Sato, S ;
Sekiya, A ;
Shibata, M .
PHYSICAL REVIEW LETTERS, 2001, 86 (18) :3950-3954
[4]  
ARAI K, 2003, P 28 INT COSM RAY C, P3085
[5]   AUTOMATIC ALIGNMENT-CONTROL SYSTEM FOR A SUSPENDED FABRY-PEROT CAVITY [J].
KAWABE, K ;
MIO, N ;
TSUBONO, K .
APPLIED OPTICS, 1994, 33 (24) :5498-5505
[6]   Large-scale cryogenic gravitational wave telescope [J].
Kuroda, K ;
Ohashi, M ;
Miyoki, S ;
Tatsumi, D ;
Sato, S ;
Ishizuka, H ;
Fujimoto, MK ;
Kawamura, S ;
Takahashi, R ;
Yamazaki, T ;
Arai, K ;
Fukushima, M ;
Waseda, K ;
Telada, S ;
Ueda, A ;
Shintomi, T ;
Yamamoto, A ;
Suzuki, T ;
Saito, Y ;
Haruyama, T ;
Sato, N ;
Tsubono, K ;
Kawabe, K ;
Ando, M ;
Ueda, KI ;
Yoneda, H ;
Musha, M ;
Mio, N ;
Moriwaki, S ;
Araya, A ;
Kanda, N ;
Tobar, ME .
INTERNATIONAL JOURNAL OF MODERN PHYSICS D, 1999, 8 (05) :557-579
[7]   AUTOMATIC ALIGNMENT OF OPTICAL INTERFEROMETERS [J].
MORRISON, E ;
MEERS, BJ ;
ROBERTSON, DI ;
WARD, H .
APPLIED OPTICS, 1994, 33 (22) :5041-5049
[8]   EXPERIMENTAL DEMONSTRATION OF AN AUTOMATIC ALIGNMENT SYSTEM FOR OPTICAL INTERFEROMETERS [J].
MORRISON, E ;
MEERS, BJ ;
ROBERTSON, DI ;
WARD, H .
APPLIED OPTICS, 1994, 33 (22) :5037-5040
[9]   Development of a multistage laser frequency stabilization for an interferometric gravitational-wave detector [J].
Nagano, S ;
Kawamura, S ;
Ando, M ;
Takahashi, R ;
Arai, K ;
Musha, M ;
Telada, S ;
Fujimoto, MK ;
Fukushima, M ;
Kozai, Y ;
Miyama, S ;
Ueda, A ;
Waseda, K ;
Yamazaki, T ;
Ishizuka, H ;
Kuroda, K ;
Matsumura, S ;
Miyakawa, O ;
Miyoki, S ;
Ohashi, M ;
Sato, S ;
Tatsumi, D ;
Tomaru, T ;
Uchiyama, T ;
Kawabe, K ;
Ohishi, N ;
Otsuka, S ;
Sekiya, A ;
Takamori, A ;
Taniguchi, S ;
Tochikubo, K ;
Tsubono, K ;
Ueda, K ;
Yamamoto, K ;
Mio, N ;
Moriwaki, S ;
Horikoshi, G ;
Kamikubota, N ;
Ogawa, Y ;
Saito, Y ;
Suzuki, T ;
Nakagawa, K ;
Ueda, K ;
Araya, A ;
Kanda, N ;
Kawashima, N ;
Mizuno, E ;
Barton, MA ;
Tsuda, N ;
Matsuda, N .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (09) :4176-4183
[10]   Development of a light source with an injection-locked Nd:YAG laser and a ring-mode cleaner for the TAMA 300 gravitational-wave detector [J].
Nagano, S ;
Barton, MA ;
Ishizuka, H ;
Kuroda, K ;
Matsumura, S ;
Miyakawa, O ;
Miyoki, S ;
Tatsumi, D ;
Tomaru, T ;
Uchiyama, T ;
Ando, M ;
Arai, K ;
Kawabe, K ;
Ohishi, N ;
Takamori, A ;
Taniguchi, S ;
Tochikubo, K ;
Tsubono, K ;
Yamamoto, K ;
Fujimoto, MK ;
Fukushima, M ;
Kawamura, S ;
Kozai, Y ;
Miyama, S ;
Ohashi, M ;
Sato, S ;
Takahashi, R ;
Telada, S ;
Yamazaki, T ;
Mio, N ;
Moriwaki, S ;
Horikoshi, G ;
Kamikubota, N ;
Ogawa, Y ;
Saito, Y ;
Suzuki, T ;
Musha, M ;
Nakagawa, K ;
Ueda, A ;
Ueda, K ;
Araya, A ;
Kanda, N ;
Nakamura, T ;
Tanaka, T ;
Sasaki, M ;
Tagoshi, H ;
Futamase, T ;
Kawashima, N ;
Mizuno, E ;
Kojima, Y .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (05) :2136-2142