Isotope beating effects in the analysis of polymer distributions by Fourier transform mass spectrometry

被引:25
作者
Easterling, ML
Amster, IJ [1 ]
van Rooij, GJ
Heeren, RMA
机构
[1] Univ Georgia, Dept Chem, Athens, GA 30602 USA
[2] FOM, Inst Atom & Mol Phys, Amsterdam, Netherlands
基金
美国国家科学基金会;
关键词
D O I
10.1016/S1044-0305(99)00091-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For Fourier transform mass spectrometry analysis of high mass ions, the signals from closely spaced isotope peaks undergo periodic destructive interference, producing a beat pattern in the time-domain signal. The mass spectra that are obtained by sampling transient signals for less than two beat periods exhibit an error in the relative abundances that-are measured. This effect is shown to cause significant errors in the measurement of the relative abundances of the components of polymer distributions, leading to errors in the derived average molecular weights for such samples. Computer simulations show that isotope beating causes this error to increase as the duration of an acquired transient becomes short compared to the beating period. This error becomes insignificant when the transient is acquired for longer than twice the beat period. Experimental data are presented for polymers in which an oligomeric distribution of monoisotopic peaks is produced by stored waveform inverse Fourier transform ejection of all C-13-containing isotope peaks. The data show that the isotope beating-induced abundance errors are eliminated when there are no isotope peaks present. (J Am Soc Mass Spectrom 1999, 10, 1074-1082) (C) 1999 American Society for Mass Spectrometry.
引用
收藏
页码:1074 / 1082
页数:9
相关论文
共 43 条
[1]  
Axelsson J, 1997, RAPID COMMUN MASS SP, V11, P209, DOI 10.1002/(SICI)1097-0231(19970131)11:2<209::AID-RCM734>3.0.CO
[2]  
2-E
[3]   HIGH-MOLECULAR-WEIGHT POLYMER ANALYSIS BY LASER MICROPROBE FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BRENNA, JT ;
CREASY, WR .
APPLIED SPECTROSCOPY, 1991, 45 (01) :80-91
[4]  
BRENNA JT, 1993, ADV CHEM SER, P129
[5]   Improved isotopic abundance measurements for high resolution Fourier transform ion cyclotron resonance mass spectra via time-domain data extraction [J].
Bresson, JA ;
Anderson, GA ;
Bruce, JE ;
Smith, RD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (08) :799-804
[6]   POLYMER ANALYSIS BY PHOTONS, SPRAYS, AND MASS-SPECTROMETRY [J].
CAMPANA, JE ;
SHENG, LS ;
SHEW, SL ;
WINGER, BE .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (06) :239-247
[7]   INVESTIGATION OF A SCREENED ELECTROSTATIC ION TRAP FOR ANALYSIS OF HIGH MASS MOLECULES BY FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
CASTORO, JA ;
KOSTER, C ;
WILKINS, CL .
ANALYTICAL CHEMISTRY, 1993, 65 (06) :784-788
[8]   ENDGROUP ANALYSIS OF POLYETHYLENE-GLYCOL POLYMERS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
DEKOSTER, CG ;
DUURSMA, MC ;
VANROOIJ, GJ ;
HEEREN, RMA ;
BOON, JJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (10) :957-962
[9]   rf capacitive coupling with efficient gated trapping in internal matrix-assisted laser desorption ionization Fourier transform ion cyclotron resonance [J].
Easterling, ML ;
Pitsenberger, CC ;
Amster, IJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (02) :195-198
[10]   MALDI FTMS analysis of polymers: improved performance using an open ended cylindrical analyzer cell [J].
Easterling, ML ;
Mize, TH ;
Amster, IJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 169 :387-400