rf capacitive coupling with efficient gated trapping in internal matrix-assisted laser desorption ionization Fourier transform ion cyclotron resonance

被引:12
作者
Easterling, ML [1 ]
Pitsenberger, CC [1 ]
Amster, IJ [1 ]
机构
[1] UNIV GEORGIA,DEPT CHEM,ATHENS,GA 30602
基金
美国国家科学基金会;
关键词
D O I
10.1016/S1044-0305(96)00252-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method to combine gated trapping and capacitive coupling into a single experiment is reported. This is achieved with a circuit that allows isolation of the electronic network that gates the trapping voltage from the circuit that enables capacitive coupling of the rf excitation signal to the trapping plates. When the capacitive coupling network is not isolated from the gated trapping network, the trapping voltage changes occur on a 100 mu s or longer timescale, which is incompatible with efficient capture of ions formed by matrix-assisted laser desorption ionization. Isolation of the two networks allows the trapping voltage to be gated with less than a 10 mu s risetime. The effectiveness of this approach is demonstrated by a set of experiments carried out with and without the benefit of the isolation of capacitive coupling from gated trapping. (C) 1997 American Society for Mass Spectrometry
引用
收藏
页码:195 / 198
页数:4
相关论文
共 15 条
[1]   ELIMINATION OF AXIAL EJECTION DURING EXCITATION WITH A CAPACITIVELY COUPLED OPEN TRAPPED-ION CELL FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :177-180
[2]   THE INFINITY CELL - A NEW TRAPPED-ION CELL WITH RADIOFREQUENCY COVERED TRAPPING ELECTRODES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CARAVATTI, P ;
ALLEMANN, M .
ORGANIC MASS SPECTROMETRY, 1991, 26 (05) :514-518
[3]  
EASTERLING ML, IN PRESS INT J MASS
[4]   ION TRAPS FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY - PRINCIPLES AND DESIGN OF GEOMETRIC AND ELECTRIC CONFIGURATIONS [J].
GUAN, SH ;
MARSHALL, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1995, 146 :261-296
[5]   DYNAMICS OF ION COUPLING IN AN FTMS ION-TRAP AND RESULTING EFFECTS ON MASS-SPECTRA, INCLUDING ISOTOPE RATIOS [J].
HUANG, JY ;
TIEDEMANN, PW ;
LAND, DP ;
MCIVER, RT ;
HEMMINGER, JC .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 134 (01) :11-21
[6]   TIME-OF-FLIGHT ICR SPECTROMETRY [J].
KOFEL, P ;
ALLEMANN, M ;
KELLERHALS, H ;
WANCZEK, KP .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 72 (1-2) :53-61
[7]   HIGH-RESOLUTION MATRIX-ASSISTED LASER DESORPTION IONIZATION OF BIOMOLECULES BY FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
KOSTER, C ;
CASTORO, JA ;
WILKINS, CL .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (19) :7572-7574
[8]   DETECTION LIMITS FOR MATRIX-ASSISTED LASER-DESORPTION OF POLYPEPTIDES WITH AN EXTERNAL ION-SOURCE FOURIER-TRANSFORM MASS-SPECTROMETER [J].
LI, YZ ;
MCIVER, RT .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (09) :743-749
[9]   FTMS METHOD FOR HIGH-RESOLUTION MATRIX-ASSISTED LASER-DESORPTION [J].
MCIVER, RT ;
LI, YZ ;
HUNTER, RL .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 132 (03) :L1-L7
[10]   A TRAPPED ION ANALYZER CELL FOR ION CYCLOTRON RESONANCE SPECTROSCOPY [J].
MCIVER, RT .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1970, 41 (04) :555-&