PET recognition of pulmonary metastases on PET/CT imaging: impact of attenuation-corrected and non-attenuation-corrected PET images

被引:55
作者
Reinhardt, MJ
Wiethoelter, N
Matthies, A
Joe, AY
Strunk, H
Jaeger, U
Biersack, HJ
机构
[1] Univ Hosp Bonn, Dept Nucl Med, D-53105 Bonn, Germany
[2] Univ Hosp Bonn, Dept Radiol, D-53105 Bonn, Germany
关键词
positron emission tomography; computed tomography; pulmonary metastases; attenuation correction;
D O I
10.1007/s00259-005-1901-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aims of this study were to assess the performance of FDG PET at PET/CT imaging for the detection of pulmonary metastases and to evaluate differences in lesion detectability on attenuation-corrected (AC) and non-attenuation corrected (NAC) PET images. Methods: The institutional PET/CT database was searched for patients with pulmonary metastases of 3-60 mm in diameter. Ninety-two patients with 438 metastases to the lungs were included in the study. The primary tumours were 33 malignant melanomas, 12 carcinomas of unknown primary, 11 colorectal carcinomas, eight differentiated thyroid carcinomas, seven aggressive non-Hodgkin's lymphomas, six head and neck cancers, three breast cancers, two prostate cancers and ten others. Lesion detectability was visually compared between PET and CT and between AC and NAC PET images using a five-point scale. Results: Of the 438 pulmonary metastases, 174 were detected with FDG PET (39.7%), six of them on NAC images only (not significant). Visual scores were higher on NAC images in 41.4% and equal in 54.6% of lesions. The sensitivity of FDG PET increased significantly from 0.405 for metastases of 5-7 mm in diameter to 0.784 for lesions of 8-10 mm and to 0.935 for lesions measuring 11-29 mm in diameter. No metastases smaller than 5 mm in diameter were seen on PET images. Conclusion: FDG PET/CT is useful for the assessment of pulmonary metastases. The frequency of lesion detection is similar for AC and NAC PET images. A reduced sensitivity of FDG PET has to be considered for lesions smaller than 11 mm in diameter.
引用
收藏
页码:134 / 139
页数:6
相关论文
共 28 条
[1]  
Bai CY, 2003, J NUCL MED, V44, P1855
[2]  
Bengel FM, 1997, EUR J NUCL MED, V24, P1091
[3]  
Beyer T, 2000, J NUCL MED, V41, P1369
[4]   Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology [J].
Beyer, T ;
Antoch, G ;
Blodgett, T ;
Freudenberg, LF ;
Akhurst, T ;
Mueller, S .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) :588-596
[5]  
Bleckmann C, 1999, J NUCL MED, V40, P2021
[6]   Exact and approximate rebinning algorithms for 3-D PET data [J].
Defrise, M ;
Kinahan, PE ;
Townsend, DW ;
Michel, C ;
Sibomana, M ;
Newport, DF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :145-158
[7]   Likelihood of malignancy in a solitary pulmonary nodule - Comparison of Bayesian analysis and results of FDG-PET scan [J].
Dewan, NA ;
Shehan, CJ ;
Reeb, SD ;
Gobar, LS ;
Scott, WJ ;
Ryschon, K .
CHEST, 1997, 112 (02) :416-422
[8]  
Erdi YE, 2004, J NUCL MED, V45, P1287
[9]  
Farquhar TH, 1999, J NUCL MED, V40, P2043
[10]   Respiration-induced attenuation artifact at PET/CT: Technical considerations [J].
Goerres, GW ;
Burger, C ;
Kamel, E ;
Seifert, B ;
Kaim, AH ;
Buck, A ;
Buehler, TC ;
von Schulthess, GK .
RADIOLOGY, 2003, 226 (03) :906-910