Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology

被引:261
作者
Beyer, T
Antoch, G
Blodgett, T
Freudenberg, LF
Akhurst, T
Mueller, S
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol, D-45147 Essen, Germany
[2] Univ Hosp Essen, Dept Nucl Med, Essen, Germany
[3] Univ Pittsburgh, Ctr Med, PET Facil, Pittsburgh, PA USA
[4] Mem Sloan Kettering Canc Ctr, New York, NY 10021 USA
关键词
PET/CT imaging; dual-modality tomography; oncology; respiration protocols;
D O I
10.1007/s00259-002-1097-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
To reduce potential mis-registration from differences in the breathing pattern between two complementary PET and CT data sets, patients are generally allowed to breathe quietly during a dual-modality scan using a combined PET/CT tomograph. Frequently, however, local mis-registration between the CT and the PET is observed. We have evaluated the appearance, magnitude, and frequency of respiration-induced artefacts in CT images of dual-modality PET/CT studies of 62 patients. Combined PET/CT scans during normal respiration were acquired in 43 subjects using single- or dual-slice CT. Nineteen patients were scanned with a special breathing protocol (limited breath-hold technique) on a single-slice PET/CT tomograph. All subjects were injected with similar to370 MBq of FDG, and PET/CT scanning commenced 1 h post injection. The CT images were reconstructed and, after appropriate scaling, used for on-line attenuation correction of the PET emission data. We found that respiration artefacts can occur in the majority of cases if no respiration protocol is used. When applying the limited breath-hold technique, the frequency of severe artefacts in the area of the diaphragm was reduced by half, and the spatial extent of respiration-induced artefacts was reduced by at least 40% compared with the acquisition protocols without any breathing instructions. In conclusion, special breathing protocols are effective and should be used for CT scans as part of combined imaging protocols using a dual-modality PET/CT tomograph. The results of this study can also be applied to multi-slice CT to potentially reduce further breathing artefacts in PET/CT imaging and to improve overall image quality.
引用
收藏
页码:588 / 596
页数:9
相关论文
共 18 条
[1]
Beyer T, 2000, J NUCL MED, V41, P1369
[2]
Beyer T, 2002, Q J NUCL MED, V46, P24
[3]
BEYER T, 2001, J NUCL MED, V42
[4]
BOERRES GW, 2002, EUR J NUCL MED, V29, P351
[5]
CARNEY J, 2002, J NUCL MED, V43
[6]
COHADE C, 2002, J NUCL MED, V43
[7]
Gambhir SS, 2001, J NUCL MED, V42, p1S
[8]
CANCER-DETECTION WITH WHOLE-BODY PET USING 2-[F-18]FLUORO-2-DEOXY-D-GLUCOSE [J].
HOH, CK ;
HAWKINS, RA ;
GLASPY, JA ;
DAHLBOM, M ;
TSE, NY ;
HOFFMAN, EJ ;
SCHIEPERS, C ;
CHOI, Y ;
REGE, S ;
NITZSCHE, E ;
MADDAHI, J ;
PHELPS, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (04) :582-589
[9]
Image registration: an essential tool for nuclear medicine [J].
Hutton, BF ;
Braun, M ;
Thurfjell, L ;
Lau, DYH .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (04) :559-577
[10]
Attenuation correction for a combined 3D PET/CT scanner [J].
Kinahan, PE ;
Townsend, DW ;
Beyer, T ;
Sashin, D .
MEDICAL PHYSICS, 1998, 25 (10) :2046-2053