Direct measurement of the evanescent field profile produced by objective-based total internal reflection fluorescence

被引:99
作者
Mattheyses, AL
Axelrod, D
机构
[1] Univ Michigan, Div Biophys Res, Ann Arbor, MI 48109 USA
[2] Dept Phys, Ann Arbor, MI 48109 USA
关键词
total internal reflection fluorescence; evanescent field profile; microscopy; index matching;
D O I
10.1117/1.2161018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Total internal reflection fluorescence (TIRF) microscopy produces a thin excitation field (the evanescent field) that nominally decays exponentially. This field is ideal for selective excitation of fluorophores near the coverslip/ sample interface. We present an experimental method, where the depth and axial profile of the evanescent field can be measured directly by microscopic observation of low refractive index fluorescently labeled spherical beads in an index-matched solution. To demonstrate the technique, through-the-objective TIRF is set up with laser excitation. In this configuration, the axial profile of the evanescent field created by either a 1.45-numerical aperture (NA) or a 1.65-NA objective fits well to a double exponential. At the coverslip/ sample interface, about 90% of the evanescent field is represented by an exponential with a decay rate consistent with that expected for a theoretical evanescent field; the remaining 10% of the field is represented by an exponential with a much longer decay constant and is identified as scattering. The approach presented here is particularly useful for investigating the quality and axial profile of the evanescent field in both laser-based and mercury arc-based through-the-objective TIRF systems where a significant amount of light scattering can occur in the illumination optics. (c) 2006 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:7
相关论文
共 8 条
[1]   Visualization of regulated exocytosis with a granule membrane probe using total internal reflection microscopy [J].
Allersma, MW ;
Wang, L ;
Axelrod, D ;
Holz, RW .
MOLECULAR BIOLOGY OF THE CELL, 2004, 15 (10) :4658-4668
[2]  
Axelrod D, 2003, METHOD ENZYMOL, V361, P1
[3]   Highly efficient optical detection of surface-generated fluorescence [J].
Enderlein, J ;
Ruckstuhl, T ;
Seeger, S .
APPLIED OPTICS, 1999, 38 (04) :724-732
[4]   Subnanometric measurements of evanescent wave penetration depth using total internal reflection microscopy combined with fluorescent correlation spectroscopy [J].
Harlepp, S ;
Robert, J ;
Darnton, NC ;
Chatenay, D .
APPLIED PHYSICS LETTERS, 2004, 85 (17) :3917-3919
[5]   FLUORESCENCE EMISSION AT DIELECTRIC AND METAL-FILM INTERFACES [J].
HELLEN, EH ;
AXELROD, D .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1987, 4 (03) :337-350
[6]   STRUCTURAL RESONANCES IN A DIELECTRIC SPHERE ILLUMINATED BY AN EVANESCENT-WAVE [J].
LIU, C ;
KAISER, T ;
LANGE, S ;
SCHWEIGER, G .
OPTICS COMMUNICATIONS, 1995, 117 (5-6) :521-531
[7]   LIGHT-EMISSION BY MAGNETIC AND ELECTRIC DIPOLES CLOSE TO A PLANE INTERFACE .1. TOTAL RADIATED POWER [J].
LUKOSZ, W ;
KUNZ, RE .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1977, 67 (12) :1607-1615
[8]   Simultaneous atomic force microscope and fluorescence measurements of protein unfolding using a calibrated evanescent wave [J].
Sarkar, A ;
Robertson, RB ;
Fernandez, JM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (35) :12882-12886