Determination of primary explosive azides in environmental samples by sequential injection amperometry

被引:20
作者
Echols, RT [1 ]
James, RR [1 ]
Aldstadt, JH [1 ]
机构
[1] ARGONNE NATL LAB,DIV ENVIRONM RES,ARGONNE,IL 60439
关键词
flow injection; sequential injection; explosives; lead azide; sodium azide; amperometry; gas diffusion;
D O I
10.1039/a605662h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of flow injection methodology to the determination of trace concentrations of primary explosives is presented, The approach is demonstrated with a sequential injection amperometric method for the determination of the azide ion (N-3(-)) The proposed method can be applied to the determination of sodium azide or lead azide, a primary explosive, without regard to other sources of lead in environmental samples, The sequential injection system used for the analysis forms the basis for a proposed field-portable instrument for the analysis of primary explosives, A microporous gas permeable membrane in a gas diffusion unit (GDU) is used to separate the analyte from other anions that can also be oxidized at the amperometric cell, The behaviour of the GDU was optimized with respect to the pH of the donor stream and the timing of the preconcentration step, A study of anions that are commonly found in environmental samples showed that the species that will interfere with the analytical signal can be removed by the GDU, Results from three water samples that were spiked with 0.40 ppm of azide are presented, RSDs in the range 3-5% were typically obtained using the method, The useful working range of the method was linear up to 0.5 ppm and non-linear up to 20 ppm (second-order model), The limit of detection was 24.6 ppb.
引用
收藏
页码:315 / 319
页数:5
相关论文
共 21 条
[1]   SPECTROPHOTOMETRIC DETERMINATION OF AZIDE WITH FERRIC PERCHLORATE [J].
ANTON, A ;
DODD, JG ;
HARVEY, AE .
ANALYTICAL CHEMISTRY, 1960, 32 (09) :1209-1210
[2]  
BRYANT JI, 1960, ANAL CHEM, V32, P759
[3]  
DZIEGIEC J, 1971, ACTA CHIM SOC SCI LO, V16, P69
[4]  
Fang Z., 1993, FLOW INJECTION SEPAR
[5]  
FRANCO DW, 1977, ANAL LETT, V10, P243
[6]   DETERMINATION OF AZIDES IN ORGANIC SOLVENTS [J].
GROVE, EL ;
BRAMAN, RS ;
NICHOLSON, SB ;
COMBS, HF .
ANALYTICAL CHEMISTRY, 1962, 34 (06) :682-&
[7]   FUNDAMENTALS OF SINUSOIDAL FLOW SEQUENTIAL INJECTION SPECTROPHOTOMETRY [J].
GUBELI, T ;
CHRISTIAN, GD ;
RUZICKA, J .
ANALYTICAL CHEMISTRY, 1991, 63 (21) :2407-2413
[8]   POLY(VINYL CHLORIDE) MATRIX MEMBRANE ELECTRODES FOR MANUAL AND FLOW-INJECTION DETERMINATION OF METAL AZIDES [J].
HASSAN, SSM ;
ELZAWAWY, FM ;
MARZOUK, SAM ;
ELNEMMA, EM .
ANALYST, 1992, 117 (11) :1683-1689
[9]  
ILCHEVA L, 1979, ACTA CHIM HUNG, P113
[10]  
JENKINS TJ, 1990, 9038 COLD REG RES EN