Intercomparison measurements by pulse transient and stepwise transient methods on Perspex and stainless steel A310

被引:7
作者
Kubicár, L [1 ]
Bohác, V [1 ]
机构
[1] Slovak Acad Sci, Inst Phys, Bratislava 84228, Slovakia
关键词
D O I
10.1068/htwu134
中图分类号
O414.1 [热力学];
学科分类号
摘要
Intercomparison measurements have been made on Perspex (polymethylmethaerylate) and stainless steel A310 by pulse transient and stepwise transient methods. Both methods belong to the transient techniques that give specific heat, thermal diffusivity, and thermal conductivity within a single measurement. Measuring times and time windows for data evaluation are given for both measuring techniques. Criteria for characteristic parameters of the ideal model by pulse transient are given. Experimental results are compared with recommended and published data for thermal conductivity, specific heat, and thermal diffusivity. Deviations from published and recommended data were found. Data uncertainties in thermal conductivity caused by these deviations are up to 6% for Perspex and up to 10% for stainless steel A310.
引用
收藏
页码:135 / 146
页数:12
相关论文
共 13 条
[1]  
[Anonymous], 1992, COMPENDIUM THERMOPHY, DOI DOI 10.1007/978-1-4615-3286-6_19
[2]  
BASILIEV LL, 1971, TEPLOFTZICHESKIE SVO
[3]  
BECK JV, 1977, PARAMTER ESTIMATION
[4]  
Carslaw H. S., 1959, CONDUCTION HEAT SOLI
[5]  
CORSAN J., 1991, HIGH TEMP HIGH PRESS, V23, P119
[6]  
KONIORCZYK P, 1996, P TEMPEKO 96, P543
[7]   A step-wise method for measuring thermophysical parameters of materials [J].
Kubicár, L ;
Bohác, V .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2000, 11 (03) :252-258
[8]  
KUBICAR L, 1990, COMPREHENSIVE ANAL E, V12
[9]  
KUBICAR L, 1999, P 1 INT C THERM PROP, P19
[10]  
KUBICAR L, 1996, P TEMPECO 96, P505