On-line combination of aqueous-sample preparation and capillary gas chromatography

被引:35
作者
Louter, AJH [1 ]
Vreuls, JJ [1 ]
Brinkman, UAT [1 ]
机构
[1] Free Univ Amsterdam, Dept Analyt Chem & Appl Spect, NL-1081 HV Amsterdam, Netherlands
关键词
reviews; sample preparation; water analysis; environmental analysis; liquid chromatography-gas chromatography; pesticides;
D O I
10.1016/S0021-9673(99)00211-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An overview is presented of methods currently in use to combine the preparation of aqueous samples on-line with capillary gas chromatography. Two approaches can be distinguished: heartcut-orientated reversed-phase liquid chromatography-gas chromatography (GC) and analyte-isolation-orientated analyte extraction-GC. These approaches either use techniques in which water is directly introduced onto the GC column, or an indirect approach in which water is eliminated, i.e., by solid-phase extraction, solid-phase microextraction or liquid-liquid extraction, prior to introduction of the analytes onto the GC column. The latter type of approach is much more successful and user friendly, and many applications have been reported. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:391 / 426
页数:36
相关论文
共 172 条
[1]   Determination of chlorinated acetic acids in drinking water by in-situ derivatization and solid phase microextraction [J].
Aikawa, B ;
Burk, RC .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1997, 66 (03) :215-224
[2]  
[Anonymous], 1991, ON LINE COUPLED LC G
[3]  
[Anonymous], 1996, ANALYST, DOI DOI 10.1039/an9962100929
[4]  
ARTHUR CL, 1992, HRC-J HIGH RES CHROM, V15, P741
[5]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[6]   ANALYSIS OF SUBSTITUTED BENZENE COMPOUNDS IN GROUNDWATER USING SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
MOTLAGH, S ;
LIM, M ;
POTTER, DW ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (05) :979-983
[7]  
ARTHUR CL, 1992, LC GC-MAG SEP SCI, V10, P656
[8]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[9]   DETERMINATION OF LOW PARTS PER BILLION LEVELS OF AMINES IN URINE BY LIQUID MEMBRANE SAMPLE CLEANUP DIRECTLY COUPLED TO A GAS-LIQUID CHROMATOGRAPH [J].
AUDUNSSON, G .
ANALYTICAL CHEMISTRY, 1988, 60 (13) :1340-1347
[10]   ONLINE COUPLING OF A GAS-CHROMATOGRAPH TO A CONTINUOUS LIQUID LIQUID EXTRACTOR [J].
BALLESTEROS, E ;
GALLEGO, M ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1990, 62 (15) :1587-1591