An overview is presented of methods currently in use to combine the preparation of aqueous samples on-line with capillary gas chromatography. Two approaches can be distinguished: heartcut-orientated reversed-phase liquid chromatography-gas chromatography (GC) and analyte-isolation-orientated analyte extraction-GC. These approaches either use techniques in which water is directly introduced onto the GC column, or an indirect approach in which water is eliminated, i.e., by solid-phase extraction, solid-phase microextraction or liquid-liquid extraction, prior to introduction of the analytes onto the GC column. The latter type of approach is much more successful and user friendly, and many applications have been reported. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:391 / 426
页数:36
相关论文
共 172 条
[41]   REVERSED-PHASE LIQUID-CHROMATOGRAPHY COUPLED ONLINE WITH CAPILLARY GAS-CHROMATOGRAPHY - USE OF AN ANION-EXCHANGE MEMBRANE TO REMOVE AN ION-PAIR REAGENT FROM THE ELUENT [J].
GOOSENS, EC ;
BEERTHUIZEN, IM ;
DEJONG, D ;
DEJONG, GJ ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1995, 40 (5-6) :267-271
[42]   REVERSED-PHASE LIQUID-CHROMATOGRAPHY COUPLED ONLINE WITH CAPILLARY GAS-CHROMATOGRAPHY .2. USE OF A SOLVENT VAPOR EXIT TO INCREASE INTRODUCTION VOLUMES AND INTRODUCTION RATES INTO THE GAS-CHROMATOGRAPH [J].
GOOSENS, EC ;
DEJONG, D ;
DEJONG, GJ ;
BRINKMAN, UAT .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1994, 6 (03) :207-215
[43]   REVERSED-PHASE LIQUID-CHROMATOGRAPHY COUPLED ONLINE WITH CAPILLARY GAS-CHROMATOGRAPHY .1. INTRODUCTION OF LARGE VOLUMES OF AQUEOUS MIXTURES THROUGH AN ON-COLUMN INTERFACE [J].
GOOSENS, EC ;
DEJONG, D ;
VANDENBERG, JHM ;
DEJONG, GJ ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1991, 552 (1-2) :489-500
[44]  
GOOSENS EC, 1990, HRC-J HIGH RES CHROM, V13, P438, DOI 10.1002/jhrc.1240130614
[45]  
GOOSENS EC, 1992, HRC-J HIGH RES CHROM, V15, P242
[46]  
GOOSENS EC, 1995, HRC-J HIGH RES CHROM, V18, P38
[47]  
Goosens EC, 1997, HRC-J HIGH RES CHROM, V20, P325
[48]   Pesticides by solid-phase microextraction. Results of a round robin test [J].
Gorecki, T ;
Mindrup, R ;
Pawliszyn, J .
ANALYST, 1996, 121 (10) :1381-1386
[49]   Effect of sample volume on quantitative analysis by solid-phase microextraction .1. Theoretical considerations [J].
Gorecki, T ;
Pawliszyn, J .
ANALYST, 1997, 122 (10) :1079-1086
[50]  
GORETTI G, 1992, HRC-J HIGH RES CHROM, V15, P51