REVERSED-PHASE LIQUID-CHROMATOGRAPHY COUPLED ONLINE WITH CAPILLARY GAS-CHROMATOGRAPHY - USE OF AN ANION-EXCHANGE MEMBRANE TO REMOVE AN ION-PAIR REAGENT FROM THE ELUENT

被引:13
作者
GOOSENS, EC [1 ]
BEERTHUIZEN, IM [1 ]
DEJONG, D [1 ]
DEJONG, GJ [1 ]
BRINKMAN, UAT [1 ]
机构
[1] FREE UNIV AMSTERDAM,DEPT ANALYT CHEM,1081 HV AMSTERDAM,NETHERLANDS
关键词
GAS CHROMATOGRAPHY; COLUMN LIQUID CHROMATOGRAPHY; ONLINE COUPLING; ION-EXCHANGE MEMBRANE; ION-PAIR REAGENT;
D O I
10.1007/BF02290356
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In order to enable the coupling of reversed-phase liquid chromatography (RPLC) with capillary gas chromatography (GC), the performance of an anion-exchange micromembrane device has been studied to remove the ion-pair reagent methanesulphonic acid from an acetonitrile/water LC eluent. The regenerant in the membrane was tetrabutylammonium hydroxide dissolved in acetonitrile/water, which effects an anion-exchange of methanesulphonate ions for regenerant hydroxide ions. The efficiency of the exchange process was found to be 99.9 %. This enabled the direct introduction of the LC eluent, free of ions and with the proper acetonitrile/water ratio, into the GC. The applicability of the on-line LC-micromembrane-GC system has been illustrated for the potential drug eltoprazine, which is quantitatively recovered with a coefficient of variation for standard solutions of 3 % at the 150 mu g/ml analyte level.
引用
收藏
页码:267 / 271
页数:5
相关论文
共 18 条
[1]   ION CHROMATOGRAPHY MASS-SPECTROMETRY FOR THE DETERMINATION OF ORGANIC AMMONIUM AND SULFATE COMPOUNDS [J].
CONBOY, JJ ;
HENION, JD ;
MARTIN, MW ;
ZWEIGENBAUM, JA .
ANALYTICAL CHEMISTRY, 1990, 62 (08) :800-807
[2]   HIGH-PERFORMANCE ANION-EXCHANGE CHROMATOGRAPHY COUPLED WITH MASS-SPECTROMETRY FOR THE DETERMINATION OF CARBOHYDRATES [J].
CONBOY, JJ ;
HENION, J .
BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (08) :397-407
[3]  
Cortes H.J., 1989, J MICROCOLUMN SEP, V1, P28
[4]   COUPLING MINIATURIZED LIQUID-CHROMATOGRAPHY TO CAPILLARY GAS-CHROMATOGRAPHY (MICRO-LC-CGC) - POSSIBILITIES OF REVERSED PHASE LC [J].
DUQUET, D ;
DEWAELE, C ;
VERZELE, M ;
MCKINLEY, S .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (11) :824-829
[5]   USE OF NONVOLATILE ION-PAIRING AGENTS FOR LIQUID-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSES WITH A MOVING-BELT INTERFACE [J].
ESCOTT, REA ;
MCDOWELL, PG ;
PORTER, NP .
JOURNAL OF CHROMATOGRAPHY, 1991, 554 (1-2) :281-292
[6]   REVERSED-PHASE LIQUID-CHROMATOGRAPHY COUPLED ONLINE WITH CAPILLARY GAS-CHROMATOGRAPHY .2. USE OF A SOLVENT VAPOR EXIT TO INCREASE INTRODUCTION VOLUMES AND INTRODUCTION RATES INTO THE GAS-CHROMATOGRAPH [J].
GOOSENS, EC ;
DEJONG, D ;
DEJONG, GJ ;
BRINKMAN, UAT .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1994, 6 (03) :207-215
[7]   REVERSED-PHASE LIQUID-CHROMATOGRAPHY COUPLED ONLINE WITH CAPILLARY GAS-CHROMATOGRAPHY .1. INTRODUCTION OF LARGE VOLUMES OF AQUEOUS MIXTURES THROUGH AN ON-COLUMN INTERFACE [J].
GOOSENS, EC ;
DEJONG, D ;
VANDENBERG, JHM ;
DEJONG, GJ ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1991, 552 (1-2) :489-500
[8]  
GROB K, 1991, ON LINE COUPLED LC G
[9]   INTERFACING ION CHROMATOGRAPHY WITH PARTICLE BEAM MASS-SPECTROMETRY FOR THE DETERMINATION OF ORGANIC ANIONIC COMPOUNDS [J].
HSU, J .
ANALYTICAL CHEMISTRY, 1992, 64 (04) :434-443
[10]  
Kim I. S., 1991, Journal of Chromatography, V589, P177