Selectivity of LC-MS/MS analysis: Implication for proteomics experiments

被引:113
作者
Gallien, Sebastien [1 ]
Duriez, Elodie [1 ]
Demeure, Kevin [1 ]
Domon, Bruno [1 ]
机构
[1] CRP Sante, Luxembourg Clin Prote Ctr LCP, L-1445 Strassen, Luxembourg
关键词
Targeted proteomics; Peptide quantification; Parallel reaction monitoring; Quadrupole-Orbitrap; SRM; MRM; MASS-SPECTROMETRY; MULTIPLEXED ASSAYS; PEPTIDE; PLASMA; PROTEINS; SRM; QUANTIFICATION; QUANTITATION; ENRICHMENT; PRECURSOR;
D O I
10.1016/j.jprot.2012.11.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The recent development of hybrid mass spectrometers with high resolution and accurate mass capabilities has opened new avenues in quantitative proteomics. A systematic study was performed to assess the quantification performances of a novel quadrupole-Orbitrap instrument operated in MS/MS mode (parallel reaction monitoring). It included the analyses of 35 isotopically labeled peptides spiked in urine samples to establish their dilution curves. The results were evaluated by replicating the analyses on a triple quadrupole instrument operated in selected reaction monitoring (SRM; often referred as multiple reaction monitoring, MRM) mode to assess and compare the gain in selectivity resulting from high resolution fragment ion analysis. The high resolving power dramatically increased the selectivity of measurements by separating ions of interest from interferences, which occurred in several cases, and thus improved the quantification performance. In addition, an experiment to assess the "co-habitation" of fragment ions in specific regions of the LC-MS/MS spectral space of a complex proteome digest was carried out. The study included the evaluation of the fragmentation patterns acquired under various experimental conditions (i.e., quadrupole isolation windows and Orbitrap resolving powers) for more than 200 peptides, which provided an experimental baseline to guide the development of methods for parallel reaction monitoring acquisition. This article is part of a Special Issue entitled: From protein structures to clinical applications. (C) 2012 Published by Elsevier B.V.
引用
收藏
页码:148 / 158
页数:11
相关论文
共 33 条
[1]   Automated Detection of Inaccurate and Imprecise Transitions in Peptide Quantification by Multiple Reaction Monitoring Mass Spectrometry [J].
Abbatiello, Susan E. ;
Mani, D. R. ;
Keshishian, Hasmik ;
Carr, Steven A. .
CLINICAL CHEMISTRY, 2010, 56 (02) :291-305
[2]   Multi-site assessment of the precision and reproducibility of multiple reaction monitoring-based measurements of proteins in plasma [J].
Addona, Terri A. ;
Abbatiello, Susan E. ;
Schilling, Birgit ;
Skates, Steven J. ;
Mani, D. R. ;
Bunk, David M. ;
Spiegelman, Clifford H. ;
Zimmerman, Lisa J. ;
Ham, Amy-Joan L. ;
Keshishian, Hasmik ;
Hall, Steven C. ;
Allen, Simon ;
Blackman, Ronald K. ;
Borchers, Christoph H. ;
Buck, Charles ;
Cardasis, Helene L. ;
Cusack, Michael P. ;
Dodder, Nathan G. ;
Gibson, Bradford W. ;
Held, Jason M. ;
Hiltke, Tara ;
Jackson, Angela ;
Johansen, Eric B. ;
Kinsinger, Christopher R. ;
Li, Jing ;
Mesri, Mehdi ;
Neubert, Thomas A. ;
Niles, Richard K. ;
Pulsipher, Trenton C. ;
Ransohoff, David ;
Rodriguez, Henry ;
Rudnick, Paul A. ;
Smith, Derek ;
Tabb, David L. ;
Tegeler, Tony J. ;
Variyath, Asokan M. ;
Vega-Montoto, Lorenzo J. ;
Wahlander, Asa ;
Waldemarson, Sofia ;
Wang, Mu ;
Whiteaker, Jeffrey R. ;
Zhao, Lei ;
Anderson, N. Leigh ;
Fisher, Susan J. ;
Liebler, Daniel C. ;
Paulovich, Amanda G. ;
Regnier, Fred E. ;
Tempst, Paul ;
Carr, Steven A. .
NATURE BIOTECHNOLOGY, 2009, 27 (07) :633-U85
[3]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[4]   Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins [J].
Anderson, L ;
Hunter, CL .
MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (04) :573-588
[5]   SISCAPA Peptide Enrichment on Magnetic Beads Using an In-line Bead Trap Device [J].
Anderson, N. Leigh ;
Jackson, Angela ;
Smith, Derek ;
Hardie, Darryl ;
Borchers, Christoph ;
Pearson, Terry W. .
MOLECULAR & CELLULAR PROTEOMICS, 2009, 8 (05) :995-1005
[6]   Review - Mass spectrometry and protein analysis [J].
Domon, B ;
Aebersold, R .
SCIENCE, 2006, 312 (5771) :212-217
[7]   Options and considerations when selecting a quantitative proteomics strategy [J].
Domon, Bruno ;
Aebersold, Ruedi .
NATURE BIOTECHNOLOGY, 2010, 28 (07) :710-721
[8]   Multiple Reaction Monitoring Cubed for Protein Quantification at the Low Nanogram/Milliliter Level in Nondepleted Human Serum [J].
Fortin, T. ;
Salvador, A. ;
Charrier, J. P. ;
Lenz, C. ;
Bettsworth, F. ;
Lacoux, X. ;
Choquet-Kastylevsky, G. ;
Lemoine, J. .
ANALYTICAL CHEMISTRY, 2009, 81 (22) :9343-9352
[9]   Clinical Quantitation of Prostate-specific Antigen Biomarker in the Low Nanogram/Milliliter Range by Conventional Bore Liquid Chromatography-Tandem Mass Spectrometry (Multiple Reaction Monitoring) Coupling and Correlation with ELISA Tests [J].
Fortin, Tanguy ;
Salvador, Arnaud ;
Charrier, Jean Philippe ;
Lenz, Cristof ;
Lacoux, Xavier ;
Morla, Aymeric ;
Choquet-Kastylevsky, Genevieve ;
Lemoine, Jerome .
MOLECULAR & CELLULAR PROTEOMICS, 2009, 8 (05) :1006-1015
[10]   Liquid chromatography/tandem mass spectrometry (highly selective selected reaction monitoring) for the analysis of isopropylthioxanthone in packaged food [J].
Gallart-Ayala, H. ;
Moyano, E. ;
Galceran, M. T. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1208 (1-2) :182-188