Focal volume confinement by submicrometer-sized fluidic channels

被引:108
作者
Foquet, M [1 ]
Korlach, J [1 ]
Zipfel, WR [1 ]
Webb, WW [1 ]
Craighead, HG [1 ]
机构
[1] Cornell Univ, Sch Appl & Engn Phys, Ithaca, NY 14853 USA
关键词
D O I
10.1021/ac035088o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microfluidic channels with two lateral dimensions smaller than 1 mum were fabricated in fused silica for high-sensitivity single-molecule detection and fluorescence correlation spectroscopy. The effective observation volumes created by these channels are similar to100 times smaller than observation volumes using conventional confocal optics and thus enable single-fluorophore detection at higher concentrations. Increased signal-to-noise ratios are also attained because the molecules are restricted to diffuse through the central regions of the excitation volume. Depending on the channel geometries, the effective dimensionality of diffusion is reduced, which is taken into account by simple solutions to diffusion models with boundaries. Driven by electrokinetic forces, analytes could be flowed rapidly through the observation volume, drastically increasing the rate of detection events and reducing data acquisition times. The statistical accuracy of single-molecule characterization is improved because all molecules are counted and contribute to the analysis. Velocities as high as 0.1 m/s were reached, corresponding to average molecular residence times in the observation volume as short as 10 mus. Applications of these nanofabricated devices for high-throughput, single-molecule detection in drug screening and genomic analysis are discussed.
引用
收藏
页码:1618 / 1626
页数:9
相关论文
共 59 条
  • [31] Fluorescence correlation spectroscopy: the technique and its applications
    Krichevsky, O
    Bonnet, G
    [J]. REPORTS ON PROGRESS IN PHYSICS, 2002, 65 (02) : 251 - 297
  • [32] Larson EJ, 2000, CYTOMETRY, V41, P203, DOI 10.1002/1097-0320(20001101)41:3<203::AID-CYTO7>3.0.CO
  • [33] 2-2
  • [34] How to detect weak pairs
    Laurence, TA
    Weiss, S
    [J]. SCIENCE, 2003, 299 (5607) : 667 - 668
  • [35] High efficiency molecular counting in solution: Single-molecule detection in electrodynamically focused microdroplet streams
    Lermer, N
    Barnes, MD
    Kung, CY
    Whitten, WB
    Ramsey, JM
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (11) : 2115 - 2121
  • [36] Zero-mode waveguides for single-molecule analysis at high concentrations
    Levene, MJ
    Korlach, J
    Turner, SW
    Foquet, M
    Craighead, HG
    Webb, WW
    [J]. SCIENCE, 2003, 299 (5607) : 682 - 686
  • [37] THERMODYNAMIC FLUCTUATIONS IN A REACTING SYSTEM - MEASUREMENT BY FLUORESCENCE CORRELATION SPECTROSCOPY
    MAGDE, D
    WEBB, WW
    ELSON, E
    [J]. PHYSICAL REVIEW LETTERS, 1972, 29 (11) : 705 - &
  • [38] Electroosmotically induced hydraulic pumping with integrated electrodes on microfluidic devices
    McKnight, TE
    Culbertson, CT
    Jacobson, SC
    Ramsey, JM
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (16) : 4045 - 4049
  • [39] Fluorescence correlation spectroscopy for the detection and study of single molecules in Biology
    Medina, MA
    Schwille, P
    [J]. BIOESSAYS, 2002, 24 (08) : 758 - 764
  • [40] Single-molecule detection by two-photon-excited fluorescence
    Mertz, J
    Xu, C
    Webb, WW
    [J]. OPTICS LETTERS, 1995, 20 (24) : 2532 - 2534