Local lymph node assay (LLNA): Comparison of different protocols by testing skin-sensitizing epoxy resin system components

被引:23
作者
Gamer, Armin O. [3 ]
Nies, Eberhard [2 ]
Vohr, Hans-Werner [1 ]
机构
[1] Bayer HealthCare, D-42096 Wuppertal, Germany
[2] BGIA, Inst Occupat Safety & Hlth German Social Accid In, D-53757 St Augustin, Germany
[3] BASF SE, D-67056 Ludwigshafen, Germany
关键词
Local lymph node assay variants; Quantification of lymph node stimulation; Vehicle effect; Potency ranking of sensitizers; Epoxy resin system components;
D O I
10.1016/j.yrtph.2008.08.018
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 [法学]; 10 [医学];
摘要
Thirteen epoxy resin system components were tested in the LLNA with regard to their sensitizing potency. Lymph node stimulation was quantified not only by measuring the incorporation of [3 HI-thymidine into the ear lymph nodes but also the counts of cells recovered from these organs. Equivalent figures were obtained with both endpoints used for the evaluation of lymph node cell proliferation if the reference stimulation indices were adjusted. When dissolved in acetone, all test substances showed skin-sensitizing potential, mainly on the boundary between "strong" and "moderate" according to common potency evaluation schemes. Replacing acetone with acetone/olive oil (4:1) as a vehicle for four selected test items, resulted in considerably lower estimated concentrations for sensitization induction. The challenges in comparing the results obtained by different LLNA variations are discussed. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:290 / 298
页数:9
相关论文
共 54 条
[1]
[Anonymous], AATEX
[2]
[Anonymous], ALT LAB ANIMALS
[3]
BASKETTER D, 2008, ATLA-ALTERN LAB ANIM, V36, P1
[4]
Basketter D.A., 1991, TOXICOL MECH METHOD, V1, P30, DOI DOI 10.3109/15376519109036523
[5]
THE PERFORMANCE OF THE LOCAL LYMPH-NODE ASSAY WITH CHEMICALS IDENTIFIED AS CONTACT ALLERGENS IN THE HUMAN MAXIMIZATION TEST [J].
BASKETTER, DA ;
SCHOLES, EW ;
KIMBER, I .
FOOD AND CHEMICAL TOXICOLOGY, 1994, 32 (06) :543-547
[6]
Strategies for identifying false positive responses in predictive skin sensitization tests [J].
Basketter, DA ;
Gerberick, GF ;
Kimber, I .
FOOD AND CHEMICAL TOXICOLOGY, 1998, 36 (04) :327-333
[7]
Information derived from sensitization test methods: Test sensitivity, false positives and false negatives [J].
Basketter, David A. ;
Kimber, Ian .
CONTACT DERMATITIS, 2007, 56 (01) :1-4
[8]
Analyses of cutaneous fluoroquinolones photoreactivity using the integrated model for the differentiation of skin reactions [J].
Blotz, A ;
Michel, L ;
Moysan, A ;
Blümel, J ;
Dubertret, L ;
Ahr, HJ ;
Vohr, HW .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 2000, 58 (01) :46-53
[9]
*CTL, 2001, CTLL8918
[10]
ICCVAM evaluation of the murine local lymph node assay - II. Conclusions and recommendations of an independent scientific peer review panel [J].
Dean, JH ;
Twerdok, LE ;
Tice, RR ;
Sailstad, DM ;
Hattan, DG ;
Stokes, WS .
REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2001, 34 (03) :258-273