Surgical gamma probe with TlBr semiconductor for identification of sentinel lymph node

被引:18
作者
da Costa, Fabio E. [1 ]
Rela, Paulo R. [1 ]
de Oliveira, Icimone B. [1 ]
Pereira, Maria C. C. [1 ]
Hamada, Margarida M. [1 ]
机构
[1] CNEN SP, IPEN, BR-05508900 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
gamma probe; lymph node; thallium bromide;
D O I
10.1109/TNS.2006.874472
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Intraoperative gamma probes have been widely used in surgery oriented to locate the sentinel lymph nodes in breast cancer and malignant melanoma during the surgery. In this paper, a surgical gamma probe using TlBr as a crystal semiconductor detector was developed. The performance of the probe with a maximum sensitivity of 10 cps/kBq and 11 mm of spatial resolution in 10 mm depth shows that the TlBr crystal is suitable to be used in a sentinel lymph node gamma probe. The final probe size was 12.7 mm diameter, 170 mm long and the detection performance met the necessary requirements to be used in radioguided surgery.
引用
收藏
页码:1403 / 1407
页数:5
相关论文
共 11 条
[1]   Identification of sentinel lymph node in breast cancer by lymphoscintigraphy and surgical gamma probe with peritumoral injection of scintimammographic agent "99mTc MIBI" [J].
Aras, G ;
Arican, P ;
Çam, R ;
Küçük, NÖ ;
Ibis, E ;
Tüzüner, A ;
Soylu, A .
ANNALS OF NUCLEAR MEDICINE, 2002, 16 (02) :121-126
[2]   A CsI(T1)-PIN photodiode gamma-ray probe [J].
Chavanelle, J ;
Parmentier, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 504 (1-3) :321-324
[3]   Sentinel node in cancer diagnosis with surgical probes [J].
Fougères, P ;
Kazandjian, A ;
Prat, V ;
Simon, H ;
Ricard, M ;
Bede, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) :34-40
[4]   Dependence of scintillation characteristics in the CsI(Tl) crystal on Tl+ concentrations under electron and alpha particles excitations [J].
Hamada, MM ;
Costa, FE ;
Pereira, MCC ;
Kubota, S .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) :1148-1153
[5]   Thallium bromide photodetectors for scintillation detection [J].
Hitomi, K ;
Muroi, O ;
Shoji, T ;
Hiratate, Y ;
Ishibashi, H ;
Ishii, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 448 (03) :571-575
[6]   Practical considerations in selecting and using intraoperative gamma probes [J].
Kotzassarlidou, M ;
Hatzipavlidou, B ;
Makridou, A ;
Kostaki, P ;
Salem, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2) :110-112
[7]  
MARCEL R, 2001, NUCL INSTRUM METHODS, V458, P26
[8]   Purification and preparation of TlBr crystals for room temperature radiation detector applications [J].
Oliveira, IB ;
Costa, FE ;
Chubaci, JFD ;
Hamada, MM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) :1224-1228
[9]   Pixellated thallium bromide detectors for gamma-ray spectroscopy and imaging [J].
Onodera, T ;
Hitomi, K ;
Shoji, T ;
Hiratate, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 525 (1-2) :199-204
[10]   CdTe and CdZnTe detectors in nuclear medicine [J].
Scheiber, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 448 (03) :513-524