Purification and preparation of TlBr crystals for room temperature radiation detector applications

被引:39
作者
Oliveira, IB [1 ]
Costa, FE
Chubaci, JFD
Hamada, MM
机构
[1] CNEN, IPEN, BR-05508900 Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, IF, BR-05508900 Sao Paulo, SP, Brazil
关键词
thallium bromide (TlBr); zone refining; crystal growth; radiation detector;
D O I
10.1109/TNS.2004.829383
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Thallium bromide (TIBr) is a semiconductor compound with a high atomic number and a wide bandgap, being a very promising material to be used as room temperature radiation detectors. In this work, commercial TlBr powder was used for growing crystals for detector applications. To reduce impurities, this material was purified by the zone refining technique. Trace impurities at ppb/ppm level were analyzed using inductively coupled plasma mass spectroscopy (ICP-MS). The efficiency of the purification was evaluated through studies of the decrease impurities concentrations in the TlBr powder and in the purified materials. The crystal quality was verified by X-ray diffraction (XRD). To evaluate the crystal as a semiconductor detector, systematic measurements of the transmittance, resistivity, and the radiation response (Am-241, Co-57, I-125 and Ba-133) gamma rays were carried out.
引用
收藏
页码:1224 / 1228
页数:5
相关论文
共 15 条
[1]   Characterization of polycrystalline TlBr films for radiographic detectors [J].
Bennett, PR ;
Shah, KS ;
Cirigano, LJ ;
Klugerman, MB ;
Moy, LP ;
Olschner, F ;
Squillante, MR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :266-270
[2]   Thallium bromide optical and radiation detectors for X-ray and gamma-ray spectroscopy [J].
Hitomi, K ;
Matsumoto, M ;
Muroi, O ;
Shoji, T ;
Hiratate, Y .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2526-2529
[3]   Improved spectrometric characteristics of thallium bromide nuclear radiation detectors [J].
Hitomi, K ;
Murayama, T ;
Shoji, T ;
Suehiro, T ;
Hiratate, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3) :372-378
[4]   Characterization of thallium bromide crystals for radiation detector applications [J].
Hitomi, K ;
Matsumoto, M ;
Muroi, O ;
Shoji, T ;
Hiratate, Y .
JOURNAL OF CRYSTAL GROWTH, 2001, 225 (2-4) :129-133
[5]   Recent progress in thallium bromide detectors for X- and γ-ray spectroscopy [J].
Hitomi, K ;
Muroi, O ;
Matsumoto, M ;
Hirabuki, R ;
Shoji, T ;
Suehiro, T ;
Hiratate, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) :365-369
[6]   Room temperature X- and gamma-ray detectors using thallium bromide crystals [J].
Hitomi, K ;
Muroi, O ;
Shoji, T ;
Suehiro, T ;
Hiratate, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) :160-164
[7]  
HITOMI K, 2002, JPN SOC APP PHYS INT
[8]  
JAZURRAHMAN I, 1987, NUCL INSTRUM METH A, V261, P427, DOI 10.1016/0168-9002(87)90350-0
[9]   The role of contacts in semiconductor gamma radiation detectors [J].
Lachish, U .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 403 (2-3) :417-424
[10]  
LUND JC, 1995, SEMICONDUCTORS ROOM, P458