Improved spectrometric characteristics of thallium bromide nuclear radiation detectors

被引:103
作者
Hitomi, K [1 ]
Murayama, T [1 ]
Shoji, T [1 ]
Suehiro, T [1 ]
Hiratate, Y [1 ]
机构
[1] Tohoku Inst Technol, Dept Elect, Taihaku Ku, Sendai, Miyagi 9828577, Japan
关键词
thallium bromide; many pass zone refining; travelling molten zone method; mu tau product; energy required to create an electron-hole pair; Klein relationship;
D O I
10.1016/S0168-9002(99)00141-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Thallium bromide (TlBr) is a compound semiconductor with a high atomic number and wide band gap. In this study, nuclear radiation detectors have been fabricated from the TlBr crystals. The TlBr crystals were grown by the horizontal travelling molten zone (TMZ) method using the materials purified by many pass zone refining. The crystals were characterized by measuring the resistivity, the mobility-lifetime (mu tau) product and the energy required to create an electron-hole pair (the epsilon value). Improved energy resolution has been obtained by the TlBr radiation detectors. At room temperature the full-width at half-maximum (FWHM) for the 59.5, 122 and 662 keV gamma-ray photo peak obtained from the detectors were 3.3, 8.8 and 29.5 keV, respectively. By comparing the saturated peak position of the TlBr detector with that of the CdTe detector, the epsilon value has been estimated to be about 5.85 eV for the TlBr crystal. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:372 / 378
页数:7
相关论文
共 16 条
[1]   APPLICATION OF HIGH-RESOLUTION SEMICONDUCTOR DETECTORS IN X-RAY EMISSION SPECTROGRAPHY [J].
BOWMAN, HR ;
HYDE, EK ;
THOMPSON, SG ;
JARED, RC .
SCIENCE, 1966, 151 (3710) :562-&
[2]   Improved performance lead iodide nuclear radiation detectors [J].
Deich, V ;
Roth, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :169-172
[3]   For the mechanism of the photoelectric primary current in insulating crystals. [J].
Hecht, Karl .
ZEITSCHRIFT FUR PHYSIK, 1932, 77 (3-4) :235-245
[4]  
HOFSTADTER R, 1949, NUCLEONICS APR
[5]   Comparison of HgI2, CdTe and Si (p-i-n) X-ray detectors [J].
Iwanczyk, JS ;
Patt, BE ;
Wang, YJ ;
Khusainov, AK .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :186-192
[6]  
JAZURRAHMAN I, 1987, NUCL INSTRUM METH A, V261, P427, DOI 10.1016/0168-9002(87)90350-0
[8]  
Lederer C.M., 1967, TABLE ISOTOPES, V6th
[9]   LEAD IODIDE NUCLEAR SPECTROMETERS [J].
LUND, JC ;
SHAH, KS ;
SQUILLANTE, MR ;
SINCLAIR, F .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :89-92
[10]   Room-temperature compound semiconductor radiation detectors [J].
McGregor, DS ;
Hermon, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (01) :101-124