Room temperature X- and gamma-ray detectors using thallium bromide crystals

被引:34
作者
Hitomi, K [1 ]
Muroi, O [1 ]
Shoji, T [1 ]
Suehiro, T [1 ]
Hiratate, Y [1 ]
机构
[1] Tohoku Inst Technol, Dept Elect, Taihaku Ku, Sendai, Miyagi 9828577, Japan
关键词
room temperature X- and gamma-ray detectors; thallium bromide; wide bandgap; equivalent noise charge;
D O I
10.1016/S0168-9002(99)00614-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Thallium bromide (TlBr) is a compound semiconductor with wide band gap (2.68 eV) and high X- and gamma-ray stopping power. The TlBr crystals were grown by the horizontal travelling molten zone (TMZ) method using purified material. Two types of room temperature X- and gamma-ray detectors were fabricated from the TlBr crystals: TlBr detectors with high detection efficiency for positron annihilation gamma-ray (511 keV) detection and TlBr detectors with high-energy resolution for low-energy X-ray detection. The detector of the former type demonstrated energy resolution of 56 keV FWHM (11%) for 511 keV gamma-rays. Energy resolution of 1.81 keV FWHM for 5.9 keV was obtained from the detector of the latter type. In order to analyze noise characteristics of the detector-preamplifier assembly, the equivalent noise charge (ENC) was measured as a function of the amplifier shaping time for the high-resolution detector. This analysis shows that parallel white noise and 1/f noise were dominant noise sources in the detector system. Current-voltage characteristics of the TlBr detector with a small Peltier cooler were also measured. Significant reduction of the detector leakage current was observed for the cooled detectors. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:160 / 164
页数:5
相关论文
共 8 条
[1]   A METHOD FOR THE DETERMINATION OF THE NOISE PARAMETERS IN PREAMPLIFYING SYSTEMS FOR SEMICONDUCTOR RADIATION DETECTORS [J].
BERTUCCIO, G ;
PULLIA, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (11) :3294-3298
[2]   Improved performance lead iodide nuclear radiation detectors [J].
Deich, V ;
Roth, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :169-172
[3]   Improved spectrometric characteristics of thallium bromide nuclear radiation detectors [J].
Hitomi, K ;
Murayama, T ;
Shoji, T ;
Suehiro, T ;
Hiratate, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3) :372-378
[4]   Characterization of indium iodide detectors for scintillation studies [J].
Shah, KS ;
Bennett, P ;
Moy, LP ;
Misra, MM ;
Moses, WW .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :215-219
[5]   ELECTRONIC NOISE IN LEAD IODIDE X-RAY-DETECTORS [J].
SHAH, KS ;
LUND, JC ;
OLSCHNER, F ;
BENNETT, P ;
ZHANG, J ;
MOY, LP ;
SQUILLANTE, MR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :85-88
[6]   CHARACTERIZATION OF THALLIUM BROMIDE NUCLEAR-DETECTORS [J].
SHAH, KS ;
OLSCHNER, F ;
MOY, LP ;
LUND, JC ;
SQUILLANTE, MR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 299 (1-3) :57-59
[7]   THALLIUM BROMIDE RADIATION DETECTORS [J].
SHAH, KS ;
LUND, JC ;
OLSCHNER, F ;
MOY, L ;
SQUILLANTE, MR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :199-201
[8]   EVALUATION OF CDTE(CL) CRYSTAL-GROWTH WITH THM AND APPLICATION TO A MULTICHANNEL DETECTOR [J].
SHOJI, T ;
ONABE, H ;
HIRATATE, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :324-330