Recent progress in thallium bromide detectors for X- and γ-ray spectroscopy

被引:48
作者
Hitomi, K [1 ]
Muroi, O [1 ]
Matsumoto, M [1 ]
Hirabuki, R [1 ]
Shoji, T [1 ]
Suehiro, T [1 ]
Hiratate, Y [1 ]
机构
[1] Tohoku Inst Technol, Dept Elect, Taihaku Ku, Sendai, Miyagi 9828577, Japan
关键词
room-temperature X- and gamma-ray detector; thallium bromide; X-ray CT;
D O I
10.1016/S0168-9002(00)00883-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent progress in the development of room-temperature TlBr detectors is presented. Higher-performance TlBr detectors have been fabricated from high-purity TlBr crystals grown by the traveling molten zone method. The TlBr crystals have exhibited large mobility-lifetime products of 2.6 x 10(-4) and 3.7 x 10(-5) cm(2)/V for electrons and holes, respectively. An energy resolution of 29.8 keV (5.8%) FWHM has been recorded for 511 keV gamma -rays with a TlBr detector at room temperature. Timing properties of the TlBr detectors have been studied by recording the coincidence timing spectra between a TlBr detector and a BaF2 scintillator coupled to a photomultiplier tube. Timing resolution of 21.3 ns FWHM has been measured for 511 keV positron annihilation gamma -rays from a Na-22 source. By using a single TlBr detector in current mode, an X-ray CT scanner system of a first-generation type has been developed. The performance of the system has been evaluated by observing tomographic images. Images with good spatial resolution have been obtained by the scanner with the TlBr detector. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:365 / 369
页数:5
相关论文
共 13 条
[1]   Improved performance lead iodide nuclear radiation detectors [J].
Deich, V ;
Roth, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :169-172
[2]   For the mechanism of the photoelectric primary current in insulating crystals. [J].
Hecht, Karl .
ZEITSCHRIFT FUR PHYSIK, 1932, 77 (3-4) :235-245
[3]   Improved spectrometric characteristics of thallium bromide nuclear radiation detectors [J].
Hitomi, K ;
Murayama, T ;
Shoji, T ;
Suehiro, T ;
Hiratate, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3) :372-378
[4]   Radiation damage effects by 25MeV protons and thermal annealing effects on thallium bromide nuclear radiation detectors [J].
Hitomi, K ;
Shoji, T ;
Suehiro, T ;
Hiratate, Y .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :213-217
[5]   Room temperature X- and gamma-ray detectors using thallium bromide crystals [J].
Hitomi, K ;
Muroi, O ;
Shoji, T ;
Suehiro, T ;
Hiratate, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) :160-164
[6]   Thallium bromide photodetectors for scintillation detection [J].
Hitomi, K ;
Muroi, O ;
Shoji, T ;
Hiratate, Y ;
Ishibashi, H ;
Ishii, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 448 (03) :571-575
[7]  
HOFSTADTER R, 1949, NUCLEONICS, V4, P2
[8]  
JAZURRAHMAN I, 1987, NUCL INSTRUM METH A, V261, P427, DOI 10.1016/0168-9002(87)90350-0
[9]   THALLIUM BROMIDE SEMICONDUCTOR X-RAY AND GAMMA-RAY DETECTORS [J].
OLSCHNER, F ;
SHAH, KS ;
LUND, JC ;
ZHANG, J ;
DALEY, K ;
MEDRICK, S ;
SQUILLANTE, MR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :504-508
[10]  
Rahman I.U., 1984, Phys. Rev. B, V29, P3500