Radiation damage effects by 25MeV protons and thermal annealing effects on thallium bromide nuclear radiation detectors

被引:10
作者
Hitomi, K [1 ]
Shoji, T [1 ]
Suehiro, T [1 ]
Hiratate, Y [1 ]
机构
[1] Tohoku Inst Technol, Dept Elect, Taihaku Ku, Sendai, Miyagi 9828577, Japan
关键词
D O I
10.1109/23.775516
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, TlBr detectors were irradiated with 25MeV protons accelerated by an AVF cyclotron. Isothermal annealing was performed to restore the performance of the detectors. In order to characterize the radiation damage and thermal annealing effects on the TlBr detectors, we measured current-voltage (I-V) characteristics, mobility-lifetime (mu tau) products and spectrometric responses. The I-V and mu tau measurements suggest that electron traps have been induced by 25MeV protons in the TlBr crystals. X- and gamma-ray energy spectra were measured for two different electronic conditions: the electric signals induced mainly by electron carriers traversing the crystal were used for one case and the signal induced by hole carriers were used in the other case. After irradiation of 25MeV protons, the Am-241 X- and gamma-ray spectra obtained in the former showed significantly degraded energy resolution. No degradation of energy resolution, however, was observed in the latter case. Noticeable improvements of the degraded detector performance have been observed after the thermal annealing.
引用
收藏
页码:213 / 217
页数:5
相关论文
共 11 条
[1]   THE USE OF A MERCURIC IODIDE DETECTOR FOR X-RAY-FLUORESCENCE ANALYSIS IN ARCHAEOMETRY [J].
CESAREO, R ;
GIGANTE, GE ;
IWANCZYK, JS ;
DABROWSKI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :583-590
[2]   Improved performance lead iodide nuclear radiation detectors [J].
Deich, V ;
Roth, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :169-172
[3]   A HGI2 X-RAY INSTRUMENT FOR THE SOVIET MARS 94 MISSION [J].
ECONOMOU, TE ;
IWANCZYK, JS ;
RIEDER, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :633-638
[4]   For the mechanism of the photoelectric primary current in insulating crystals. [J].
Hecht, Karl .
ZEITSCHRIFT FUR PHYSIK, 1932, 77 (3-4) :235-245
[5]  
HITOMI K, IN PRESS NUCL INST A
[6]   Application of cadmium telluride detector to high speed X-ray CT scanner [J].
Hori, K ;
Fujimoto, T ;
Kawanishi, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :397-401
[7]   The effects of 199 MeV proton radiation damage on CdZnTe photon detectors [J].
Hull, EL ;
Pehl, RH ;
Varnell, LS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :870-873
[8]   EFFECTS PRODUCED BY FAST NEUTRON BOMBARDMENT OF GE(LI) GAMMA RAY DETECTORS [J].
KRANER, HW ;
CHASMAN, C ;
JONES, KW .
NUCLEAR INSTRUMENTS & METHODS, 1968, 62 (02) :173-+
[9]   Irradiation effects on Au-Si nuclear detectors by 10 MeV alpha-particles [J].
Ohba, K ;
Mito, A ;
Wakamatsu, M ;
Ito, S ;
Shoji, T ;
HIratate, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :76-78
[10]   Energy selective imaging systems based on monolithic CdZnTe arrays operated in a high speed counting mode [J].
Polichar, R ;
Schirato, R ;
Shreve, D ;
Reed, J ;
Polichar, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :323-330