Impact of adsorption isotherm parameters on the performances of enantioseparation using simulated moving bed chromatography

被引:32
作者
Kaspereit, M
Jandera, P
Skavrada, M
Seidel-Morgenstern, A [1 ]
机构
[1] Max Planck Inst Dynamik Komplexer Technischer Sys, D-39120 Magdeburg, Germany
[2] Univ Pardubice, Dept Analyt Chem, Pardubice 53210, Czech Republic
[3] Univ Magdeburg, Inst Verfahrenstech, D-39106 Magdeburg, Germany
关键词
adsorption isotherms; enantiomer separation; simulated moving bed chromatography; preparative chromatography; mandelic acid;
D O I
10.1016/S0021-9673(01)01341-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Often there are several chromatographic systems, i.e., combinations of mobile and stationary phases, available to solve a certain separation problem. Essential differences of these chromatographic systems are the separation factors and the efficiencies. For preparative applications in addition also the column saturation capacities and solubility limits are of importance. The impact of all these parameters appears to be rather well understood for conventional overloaded elution chromatography using a single column. In the last years the continuous simulated moving bed (SMB) process was increasingly used as a powerful alternative to batch elution since increased productivities and reduced solvent consumptions could be realised. However, the selection of suitable chromatographic systems is more, sophisticated for this process. In this paper five different chromatographic systems capable of separating the enantiomers of mandelic acid are compared based on the achievable productivities using SMB chromatography. For these five systems the adsorption isotherms have been determined experimentally. Subsequently, an analysis of the SMB process was performed numerically using a well-established model. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:249 / 262
页数:14
相关论文
共 21 条
[1]   Design and optimisation of a simulated moving bed unit: role of deviations from equilibrium theory [J].
Biressi, G ;
Ludemann-Hombourger, O ;
Mazzotti, M ;
Nicoud, RM ;
Morbidelli, M .
JOURNAL OF CHROMATOGRAPHY A, 2000, 876 (1-2) :3-15
[2]   Adsorption isotherms of nonionic surfactants in SBA-15 measured by micro-column chromatography [J].
Findenegg, G. H. ;
Eltekov, A. Y. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) :236-240
[3]   Optimal operation of simulated moving-bed units for non-linear chromatographic separations - II. Bi-Langmuir isotherm [J].
Gentilini, A ;
Migliorini, C ;
Mazzotti, M ;
Morbidelli, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 805 (1-2) :37-44
[4]   Design of the simulated moving bed process based on adsorption isotherm measurements using a perturbation method [J].
Heuer, C ;
Küsters, E ;
Plattner, T ;
Seidel-Morgenstern, A .
JOURNAL OF CHROMATOGRAPHY A, 1998, 827 (02) :175-191
[5]   Effect of the mobile phase on the retention behaviour of optical isomers of carboxylic acids and amino acids in liquid chromatography on bonded Teicoplanin columns [J].
Jandera, P ;
Skavrada, M ;
Klemmová, K ;
Backovská, V ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2001, 917 (1-2) :123-133
[6]   Simulated moving-bed chromatography and its application to chirotechnology [J].
Juza, M ;
Mazzotti, M ;
Morbidelli, M .
TRENDS IN BIOTECHNOLOGY, 2000, 18 (03) :108-118
[7]   THERMODYNAMICS OF MONOLAYERS [J].
KEMBALL, C ;
RIDEAL, EK ;
GUGGENHEIM, EA .
TRANSACTIONS OF THE FARADAY SOCIETY, 1948, 44 (12) :948-954
[8]   Frontal analysis method to determine competitive adsorption isotherms [J].
Lisec, O ;
Hugo, P ;
Seidl-Morgenstern, A .
JOURNAL OF CHROMATOGRAPHY A, 2001, 908 (1-2) :19-34
[9]   Coupling of simulated moving bed chromatography and fractional crystallisation for efficient enantioseparation [J].
Lorenz, H ;
Sheehan, P ;
Seidel-Morgenstern, A .
JOURNAL OF CHROMATOGRAPHY A, 2001, 908 (1-2) :201-214
[10]   Standing wave analysis of SMB chromatography: Linear systems [J].
Ma, Z ;
Wang, NHL .
AICHE JOURNAL, 1997, 43 (10) :2488-2508