Optimal operation of simulated moving-bed units for non-linear chromatographic separations - II. Bi-Langmuir isotherm

被引:65
作者
Gentilini, A
Migliorini, C
Mazzotti, M
Morbidelli, M
机构
[1] ETH Zurich, Tech Chem Lab, CH-8092 Zurich, Switzerland
[2] ETH Zurich, Inst Automat, CH-8092 Zurich, Switzerland
[3] ETH Zurich, Inst Verfahrenstech, CH-8092 Zurich, Switzerland
关键词
simulated moving-bed chromatography; bi-Langmuir isotherms; adsorption isotherms;
D O I
10.1016/S0021-9673(98)00006-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Several important theoretical results have been previously obtained to predict the behaviour of continuous chromatographic separation units in the case of Langmuirian type of isotherms. Concerning separation of binary mixtures in a non-adsorbable carrier with SMB units, stoichiometric and non-stoichiometric Langmuir and modified Langmuir have been considered in the frame of equilibrium theory. For these isotherms explicit constraints on the operating parameters have been found to achieve complete separation (M. Mazzotti, G. Storti, M. Morbidelli, J. Chromatogr. A 769 (1997) 3; M. Mazzotti, G. Storti, M. Morbidelli, AIChE J, 42 (1996) 2784; M. Mazzotti, M. Pedeferri, M. Morbidelli, in: Chiral Europe '96 Symposium, Spring Innovations Limited, Stockport, UK, 1996); the design of the SMB unit was then reduced to the analysis of the so-called region of complete separation for the operating parameters. In this paper, the same result is presented for the bi-Langmuir case, which can avoid the constant selectivity limit of the Langmuir isotherms. Langmuir and bi-langmuir isotherms fitting the same set of data taken from the literature were then used here to show the difference in the prediction of the region of complete separation. Finally an analysis of non-linearity effects on performance parameters is presented as a useful criterion for optimization of the separation performances. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:37 / 44
页数:8
相关论文
共 27 条
[1]  
Broughton DB, 1961, U. S. Patent, Patent No. [2,985,589, 2985589]
[2]   Laboratory-developed simulated moving bed for chiral drug separations - Design of the system and separation of tramadol enantiomers [J].
Cavoy, E ;
Deltent, MF ;
Lehoucq, S ;
Miggiano, D .
JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (01) :49-57
[3]   COMPLETE DESIGN OF A SIMULATED MOVING-BED [J].
CHARTON, F ;
NICOUD, RM .
JOURNAL OF CHROMATOGRAPHY A, 1995, 702 (1-2) :97-112
[4]   MODELING OF THE ADSORPTION BEHAVIOR AND THE CHROMATOGRAPHIC BAND PROFILES OF ENANTIOMERS - BEHAVIOR OF METHYL MANDELATE ON IMMOBILIZED CELLULOSE [J].
CHARTON, F ;
JACOSON, SC ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY, 1993, 630 (1-2) :21-35
[5]   PREPARATIVE RESOLUTION OF PRAZIQUANTEL ENANTIOMERS BY SIMULATED COUNTERCURRENT CHROMATOGRAPHY [J].
CHING, CB ;
LIM, BG ;
LEE, EJD ;
NG, SC .
JOURNAL OF CHROMATOGRAPHY, 1993, 634 (02) :215-219
[6]   Experimental and theoretical study of the adsorption behavior and mass transfer kinetics of propranolol enantiomers on cellulase protein as the selector [J].
Fornstedt, T ;
Zhong, GM ;
Bensetiti, Z ;
Guiochon, G .
ANALYTICAL CHEMISTRY, 1996, 68 (14) :2370-2378
[7]   Thermodynamic study of an unusual chiral separation. Propranolol enantiomers on an immobilized cellulase [J].
Fornstedt, T ;
Sajonz, P ;
Guiochon, G .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (06) :1254-1264
[8]   Applications of simulated moving-bed chromatography to the separation of the enantiomers of chiral drugs [J].
Francotte, ER ;
Richert, P .
JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (01) :101-107