摘要
Objectives: To compare the diagnostic performance provided by two- (film and digital radiography) and three-dimensional imaging modalities (TACT slices and TACT pseudoholograms) in the detection of primary caries. Methods: Forty-two extracted human posterior teeth were mounted and imaged with conventional film and direct digital radiography. Free-hand positioning of a dental X-ray source was used for all exposures. From the digital images, iteratively restored TACT slices and TACT pseudoholograms were generated. Film images were viewed on a viewbox, Digital format images were viewed on a high-resolution monitor. Eight observers used a five-point scale to score the presence or absence of occlusal and proximal caries using the four Image modalities. Observers' assessments were compared with the histological examination of tooth sections. Possible differences in ROG curve areas among image modalities, observers, and surfaces were assessed by ANOVA. Intra- and interobserver reliability as indicated by intraclass correlation was also calculated. Results: There were no statistically significant differences between the diagnostic performances of film, digital radiography, TACT slices and TACT pseudoholograms in the detection of caries (P = 0.310). Intraclass correlation indicated the highest concordance both within and between observers when film was used for the evaluation. Conclusions: Under the experimental conditions of this study, three-dimensional TACT images did not improve caries detection over him or digital radiography. Further research should investigate the effects of imaging variables on TACT's diagnostic efficacy.
引用
收藏
页码:152 / 157
页数:6
相关论文
共 14 条
[1]   CLINICAL EFFICACY OF DENTAL RADIOGRAPHY IN THE DETECTION OF DENTAL-CARIES AND PERIODONTAL-DISEASES [J].
DOUGLASS, CW ;
VALACHOVIC, RW ;
WIJESINHA, A ;
CHAUNCEY, HH ;
KAPUR, KK ;
MCNEIL, BJ .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1986, 62 (03) :330-339
[2]   RADIOGRAPHIC DIAGNOSES AND TREATMENT DECISIONS ON APPROXIMAL CARIES [J].
ESPELID, I .
COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 1986, 14 (05) :265-270
[4]   COMPUTERIZED TOMOSYNTHESIS OF DENTAL-TISSUES [J].
GROENHUIS, RAJ ;
WEBBER, RL ;
RUTTIMANN, UE .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1983, 56 (02) :206-214
[5]  
GRONDAHL HG, 1979, SWED DENT J, V3, P101
[6]   Detection of peri-implant bone changes with axial tomosynthesis [J].
Horton, RA ;
Ludlow, JB ;
Webber, RL ;
Gates, W ;
Nason, RH ;
Reboussin, D .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1996, 81 (01) :124-129
[7]   Detection of approximal caries with a storage phosphor system. A comparison of enhanced digital images with dental X-ray film [J].
Moystad, A ;
Svanaes, DB ;
Risnes, S ;
Larheim, TA ;
Grondahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (04) :202-206
[8]   Tuned aperture computed tomography and detection of recurrent caries [J].
Nair, MK ;
Tyndall, DA ;
Ludlow, JB ;
May, K .
CARIES RESEARCH, 1998, 32 (01) :23-30
[9]   A comparison of Kodak Ektaspeed Plus film and the Siemens Sidexis digital imaging system for caries detection using receiver operating characteristic analysis [J].
Tyndall, DA ;
Ludlow, JB ;
Platin, E ;
Nair, M .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1998, 85 (01) :113-118
[10]   TACT imaging of primary caries [J].
Tyndall, DA ;
Clifton, TL ;
Webber, RL ;
Ludlow, JB ;
Horton, RA .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1997, 84 (02) :214-225