In vitro aerosol delivery and regional airway surface liquid concentration of a liposomal cationic peptide

被引:50
作者
Lange, CF
Hancock, REW
Samuel, J
Finlay, WH [1 ]
机构
[1] Univ Alberta, Dept Mech Engn, Aerosol Res Lab Alberta, Edmonton, AB T6G 2G8, Canada
[2] Univ British Columbia, Dept Immunol & Microbiol, Vancouver, BC V6T 1Z3, Canada
[3] Univ Alberta, Fac Pharm, Edmonton, AB T6G 2N8, Canada
关键词
cationic peptide; liposome encapsulation; nebulization efficiency; lung deposition simulation;
D O I
10.1002/jps.1115
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A liposome encapsulation was optimized for the entrapment and aerosol delivery of an alpha -helical cationic peptide, CM3, which had shown good antimicrobial and antiendotoxin activity in vitro. The encapsulation procedure and the phospholipids used were selected to maximize both the encapsulation and nebulization efficiencies, without compromising liposomal integrity during nebulization. The best compromise was found with dimyristoyl phosphatidylcholine and dimyristoyl phosphatidylglycerol (3:1 molar ratio), which allowed for peptide encapsulation levels of 730 mug/mL using 30 MM lipid concentration. The aerosol produced with the selected liposomal formulation was subsequently analyzed for determination of size distribution and nebulizer efficiencies. These quantities were used as input for a mathematical lung deposition model, which predicted local lung depositions of the liposomal peptides for three models of lung geometry and breathing patterns: an adult, an 8-year-old child, and a 4-year-old child. The deposition results were then applied to a novel model of airway surface liquid in the lung to assess the concentration of the deposited peptide. The resulting concentration estimates indicate that the minimum inhibitory levels of CM3 can be reached over most part of the tracheobronchial region in the adult model, and can be exceeded throughout the same region in both pediatric model subjects, using a valved jet nebulizer with a 2.5mL volume fill. (C) 2001 Wiley-Liss, Inc. and the American Pharmaceutical Association.
引用
收藏
页码:1647 / 1657
页数:11
相关论文
共 55 条
[1]   Nebulisers for the generation of liposomal aerosols [J].
Bridges, PA ;
Taylor, KMG .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1998, 173 (1-2) :117-125
[2]   An investigation of some of the factors influencing the jet nebulisation of liposomes [J].
Bridges, PA ;
Taylor, KMG .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2000, 204 (1-2) :69-79
[3]   RESPIRATORY AND ABDOMINAL MUSCLE RESPONSES TO EXPIRATORY THRESHOLD LOADING IN CYSTIC-FIBROSIS [J].
CERNY, F ;
ARMITAGE, L ;
HIRSCH, JA ;
BISHOP, B .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 72 (03) :842-850
[4]   EXPERIMENTAL MEASUREMENTS AND EMPIRICAL MODELING OF THE REGIONAL DEPOSITION OF INHALED PARTICLES IN HUMANS [J].
CHAN, TL ;
LIPPMANN, M .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1980, 41 (06) :399-408
[5]  
Cullis P. R, 1987, LIPOSOMES BIOPHYSICS, P39
[6]  
Davis C. W., 1997, AIRWAY MUCUS BASIC M, P149
[7]  
DENYER J, 1996, ISAM FOC S AER THER, P4
[8]   RhDNase I aerosol deposition and related factors in cystic fibrosis [J].
Diot, P ;
Palmer, LB ;
Smaldone, A ;
deCelieGermana, J ;
Grimson, R ;
Smaldone, GC .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 156 (05) :1662-1668
[9]   TECHNETIUM-99M AS A MARKER OF LIPOSOMAL DEPOSITION AND CLEARANCE IN THE HUMAN-LUNG [J].
FARR, SJ ;
KELLAWAY, IW ;
PARRYJONES, DR ;
WOOLFREY, SG .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1985, 26 (03) :303-316
[10]   Regional deposition of inhaled hygroscopic aerosols: In vivo SPECT compared with mathematical modeling [J].
Finlay, WH ;
Stapleton, KW ;
Chan, HK ;
Zuberbuhler, P ;
Gonda, I .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (01) :374-383