Do design variations in the artificial disc influence cervical spine biomechanics? A finite element investigation

被引:51
作者
Faizan, Ahmad [1 ,2 ,3 ,4 ]
Goel, Vijay K. [1 ,2 ,3 ,4 ]
Garfin, Steven R. [5 ]
Bono, Christopher M. [6 ]
Serhan, Hassan [7 ]
Biyani, Ashok [1 ,2 ,3 ,4 ]
Elgafy, Hossein [1 ,2 ,3 ,4 ]
Krishna, Manoj [8 ]
Friesem, Tai [8 ]
机构
[1] Univ Toledo, E CORE, Dept Bioengn, Coll Engn, 5046 NI,MS 303, Toledo, OH 43606 USA
[2] Univ Toledo, E CORE, Dept Orthopaed Surg, Coll Engn, Toledo, OH 43606 USA
[3] Univ Toledo, E CORE, Dept Bioengn, Coll Med, Toledo, OH 43606 USA
[4] Univ Toledo, E CORE, Dept Orthopaed Surg, Coll Med, Toledo, OH 43606 USA
[5] Univ Calif San Diego, Dept Orthopaed, San Diego, CA 92103 USA
[6] Harvard Med Sch, Brigham & Womens Hosp, Boston, MA USA
[7] DePuy Spine, Raynham, MA USA
[8] Univ Hosp North Tees, Stockton On Tees, England
关键词
Cervical; Disc replacement; Finite element; Biomechanics; Design variation;
D O I
10.1007/s00586-009-1211-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Various ball and socket-type designs of cervical artificial discs are in use or under investigation. Many artificial disc designs claim to restore the normal kinematics of the cervical spine. What differentiates one type of design from another design is currently not well understood. In this study, authors examined various clinically relevant parameters using a finite element model of C3-C7 cervical spine to study the effects of variations of ball and socket disc designs. Four variations of ball and socket-type artificial disc were placed at the C5-C6 level in an experimentally validated finite element model. Biomechanical effects of the shape (oval vs. spherical ball) and location (inferior vs. superior ball) were studied in detail. Range of motion, facet loading, implant stresses and capsule ligament strains were computed to investigate the influence of disc designs on resulting biomechanics. Motions at the implant level tended to increase following disc replacement. No major kinematic differences were observed among the disc designs tested. However, implant stresses were substantially higher in the spherical designs when compared to the oval designs. For both spherical and oval designs, the facet loads were lower for the designs with an inferior ball component. The capsule ligament strains were lower for the oval design with an inferior ball component. Overall, the oval design with an inferior ball component, produced motion, facet loads, implant stresses and capsule ligament strains closest to the intact spine, which may be key to long-term implant survival.
引用
收藏
页码:S653 / S662
页数:10
相关论文
共 26 条
[1]
Wear analysis of the Bryan Cervical Disc prosthesis [J].
Anderson, PA ;
Rouleau, JP ;
Bryan, VE ;
Carlson, CS .
SPINE, 2003, 28 (20) :S186-S194
[2]
Anderson Paul A, 2004, Spine J, V4, p303S, DOI 10.1016/j.spinee.2004.07.026
[3]
Changes in adjacent-level disc pressure and facet joint force after cervical arthroplasty compared with cervical discectomy and fusion [J].
Chang, Ung-Kyu ;
Kim, Daniel H. ;
Lee, Max C. ;
Willenberg, Rafer ;
Kim, Se-Hoon ;
Lim, Jesse .
JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (01) :33-39
[4]
Uncinate processes and Luschka joints influence the biomechanics of the cervical spine: Quantification using a finite element model of the C5-C6 segment [J].
Clausen, JD ;
Goel, VK ;
Traynelis, VC ;
Scifert, J .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (03) :342-347
[5]
Clausen JD, 1996, EXPERIMENTAL AND THE
[6]
DiAngelo Denis J, 2004, Neurosurg Focus, V17, pE7
[7]
Biomechanical testing of an artificial cervical joint and an anterior cervical plate [J].
DiAngelo, DJ ;
Roberston, JT ;
Metcalf, NH ;
McVay, BJ ;
Davis, RC .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2003, 16 (04) :314-323
[8]
Load-Sharing Between Anterior and Posterior Elements in a Lumbar Motion Segment Implanted With an Artificial Disc [J].
Dooris, Andrew P. ;
Goel, Vijay K. ;
Grosland, Nicole M. ;
Gilbertson, Lars G. ;
Wilder, David G. .
SPINE, 2001, 26 (06) :E122-E129
[9]
Faizan A, 2008, PLACEMENT ARTIFICIAL
[10]
Faizan A., 2008, INVESTIGATION CERVIC