SonoAVC: a novel method of automatic volume calculation

被引:73
作者
Raine-Fenning, N. [1 ]
Jayaprakasan, K.
Clewes, J.
Joergner, I. [2 ]
Bonaki, S. Dehghani [2 ]
Chamberlain, S.
Devlin, L.
Priddle, H.
Johnson, I.
机构
[1] Univ Nottingham, Queens Med Ctr, Acad Div Reproduct Med & Surg, Sch Human Dev,NURTURE, Nottingham NG7 2UH, England
[2] GE Med Syst, Zipf, Austria
关键词
3D ultrasound; automated measurement; follicle; ovary; SonoAVC; VOCAL; volume calculation;
D O I
10.1002/uog.5359
中图分类号
O42 [声学];
学科分类号
070206 [声学]; 082403 [水声工程];
摘要
Objectives To assess the ability of the new software SonoAVC to measure follicular volume and to compare these volume calculations with those made by conventional methods. Methods Three-dimensional ultrasound imaging was used to acquire volumetric data from the ovaries of 51 women undergoing controlled ovarian stimulation as part of in-vitro fertilization treatment. All assessments were performed on the day of oocyte retrieval and the true volume of each follicle was ascertained by manual measurement of the follicular aspirate. SonoAVC was used to automatically measure the volume of follicles and to provide three perpendicular diameters (xyz diameters), which were used to estimate volume using the sphere formula. The sphere formula was also used to estimate the volume from manual measurements of follicle diameter derived from conventional two-dimensional (2D) displays. Virtual Organ Computer-aided AnaLysis (VOCAL) was also used to measure volume, and the validity of each technique was compared using limits of agreement. Results Two hundred and twenty-four follicles with a mean follicular volume of 3.7 (range, 0.4-16.2) cm(3) were studied. SonoAVC provided highly accurate automatic follicular volume measurements in all cases. Volume estimations made from the automatic maximal follicular diameter measurements (xyz diameters) were less valid. VOCAL proved highly valid but was less accurate than SonoAVC. Volumes estimated from manually derived follicular diameter measurements were the least accurate. Conclusions SonoAVC provides highly valid, automatic measurements of follicular volume. These measurements are more accurate than volumes estimated from 2D manual measurements, automated measurements of follicular diameter and those calculated using VOCAL. Copyright (C) 2008 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:691 / 696
页数:6
相关论文
共 7 条
[1]
Three-dimensional versus two-dimensional ultrasound measurement of follicular volume: Are they comparable? [J].
Ahmed Amer ;
Mohamad Eid Hammadeh ;
Mohamed Kolkailah ;
Abdel-Al Ghandour .
Archives of Gynecology and Obstetrics, 2003, 268 (3) :155-157
[2]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]
Transvaginal three-dimensional ultrasound: Accuracy of follicular volume measurements [J].
KyeiMensah, A ;
Zaidi, J ;
Pittrof, R ;
Shaker, A ;
Campbell, S ;
Tan, SL .
FERTILITY AND STERILITY, 1996, 65 (02) :371-376
[4]
PENZIAS AS, 1994, FERTIL STERIL, V62, P1274
[5]
Automated follicle tracking facilitates standardization and may improve work flow [J].
Raine-Fenning, N. ;
Jayaprakasan, K. ;
Clewes, J. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 30 (07) :1015-1018
[6]
The interobserver reliability and validity of volume calculation from three-dimensional ultrasound datasets in the in vitro setting [J].
Raine-Fenning, NJ ;
Clewes, JS ;
Kendall, NR ;
Bunkheila, AK ;
Campbell, BK ;
Johnson, IR .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 21 (03) :283-291
[7]
WITTMAACK FM, 1994, FERTIL STERIL, V62, P1205