Transvaginal three-dimensional ultrasound: Accuracy of follicular volume measurements

被引:92
作者
KyeiMensah, A
Zaidi, J
Pittrof, R
Shaker, A
Campbell, S
Tan, SL
机构
[1] UCL HOSP, KINGS COLL, SCH MED & DENT, LONDON WOMENS CLIN, LONDON, ENGLAND
[2] UCL HOSP, KINGS COLL, SCH MED & DENT, DEPT OBSTET & GYNAECOL, LONDON, ENGLAND
[3] MCGILL UNIV, ROYAL VICTORIA HOSP, MONTREAL, PQ H3A 1A1, CANADA
关键词
accuracy; follicular volume; three-dimensional US;
D O I
10.1016/S0015-0282(16)58102-3
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To evaluate the accuracy of three-dimensional (3-D) ultrasound (US) follicular volume measurements. Design: Prospective clinical study. Setting: A tertiary referral center for assisted reproduction. Patients: Twenty-five patients undergoing ovarian stimulation for IVF-ET using the long protocol of GnRH agonist. Intervention: Transvaginal two-dimensional (2-D) and 3-D ovarian scan performed immediately before US-directed follicle aspiration. Main Outcome Measures: The volume of follicular fluid aspirated was compared with the corresponding volume of the follicle measured by 3-D US and with the conventional 2-D US volume measurement calculated using the formula pi/6 (D-1 x D-2 x D-3) Limits of agreement and 95% confidence intervals were calculated and systematic bias between the methods was analyzed. Results: The limits of agreement between the volume of follicular aspirate and follicular volume determined by US were +0.96 to -0.43 mt for 3-D measurements and +3.47 to -2.42 mt for 2-D measurements. Conclusions: The true volume of ovarian follicles, within the clinically useful range for IVF-ET cycles, is measured more accurately by a 3-D US system than by 2-D US techniques.
引用
收藏
页码:371 / 376
页数:6
相关论文
共 18 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
BLASS HG, 1995, ULTRASOUND OBST GYN, V5, P228
[3]   OVARIAN MORPHOLOGY, ENDOCRINE FUNCTION AND INTRA-FOLLICULAR BLOOD-FLOW DURING THE PERI-OVULATORY PERIOD [J].
COLLINS, W ;
JURKOVIC, D ;
BOURNE, T ;
KURJAK, A ;
CAMPBELL, S .
HUMAN REPRODUCTION, 1991, 6 (03) :319-324
[4]   ULTRASONIC CONTROL WITHOUT HORMONE DETERMINATION FOR OVULATION INDUCTION IN IN-VITRO FERTILIZATION-EMBRYO TRANSFER WITH GONADOTROPIN-RELEASING-HORMONE ANALOG AND HUMAN MENOPAUSAL GONADOTROPIN [J].
GOLAN, A ;
HERMAN, A ;
SOFFER, Y ;
BUKOVSKY, I ;
RONEL, R .
HUMAN REPRODUCTION, 1994, 9 (09) :1631-1633
[5]  
GONZALEZ CJ, 1988, FERTIL STERIL, V50, P657
[6]   3-DIMENSIONAL ULTRASOUND FOR THE ASSESSMENT OF UTERINE ANATOMY AND DETECTION OF CONGENITAL-ANOMALIES - A COMPARISON WITH HYSTEROSALPINGOGRAPHY AND 2-DIMENSIONAL SONOGRAPHY [J].
JURKOVIC, D ;
GEIPEL, A ;
GRUBOECK, K ;
JAUNIAUX, E ;
NATUCCI, M ;
CAMPBELL, S .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1995, 5 (04) :233-237
[7]   IS THE QUALITY OF TRANSVAGINAL IMAGES SUPERIOR TO TRANSABDOMINAL ONES UNDER MATCHED CONDITIONS [J].
KOSSOFF, G ;
GRIFFITHS, KA ;
DIXON, CE .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1991, 1 (01) :29-35
[8]   INVITRO FERTILIZATION AND THE OVARIAN HYPERSTIMULATION SYNDROME [J].
MACDOUGALL, MJ ;
TAN, SL ;
JACOBS, HS .
HUMAN REPRODUCTION, 1992, 7 (05) :597-600
[9]   VOLUME SCANNING IN THE EVALUATION OF FETAL MALFORMATIONS - A NEW DIMENSION IN PRENATAL-DIAGNOSIS [J].
MERZ, E ;
BAHLMANN, F ;
WEBER, G .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1995, 5 (04) :222-227
[10]  
PENZIAS AS, 1994, FERTIL STERIL, V62, P1274