Potentials and Limitations of Real-Time Elastography for Prostate Cancer Detection: A Whole-Mount Step Section Analysis

被引:20
作者
Junker, Daniel [1 ]
Schaefer, Georg [2 ,3 ]
Aigner, Friedrich [1 ]
Schullian, Peter [1 ]
Pallwein-Prettner, Leo [4 ]
Bektic, Jasmin [3 ]
Horninger, Wolfgang [3 ]
Halpern, Ethan J. [5 ]
Frauscher, Ferdinand [1 ]
机构
[1] Med Univ Innsbruck, Dept Radiol, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Dept Pathol, A-6020 Innsbruck, Austria
[3] Med Univ Innsbruck, Dept Urol, A-6020 Innsbruck, Austria
[4] Hosp Sisters Char, Dept Radiol, A-4020 Linz, Austria
[5] Thomas Jefferson Univ, Thomas Jefferson Prostate Diagnost Ctr, Philadelphia, PA 19107 USA
关键词
RADICAL PROSTATECTOMY; TRANSITION ZONE; ULTRASOUND; DIAGNOSIS; BIOPSIES; TISSUE;
D O I
10.1100/2012/193213
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
070301 [无机化学]; 070403 [天体物理学]; 070507 [自然资源与国土空间规划学]; 090105 [作物生产系统与生态工程];
摘要
Objectives. To evaluate prostate cancer (PCa) detection rates of real-time elastography (RTE) in dependence of tumor size, tumor volume, localization and histological type. Materials and Methods. Thirdy-nine patients with biopsy proven PCa underwent RTE before radical prostatectomy (RPE) to assess prostate tissue elasticity, and hard lesions were considered suspicious for PCa. After RPE, the prostates were prepared as whole-mount step sections and were compared with imaging findings for analyzing PCa detection rates. Results. RTE detected 6/62 cancer lesions with a maximum diameter of 0-5 mm (9.7%), 10/37 with a maximum diameter of 6-10 mm (27%), 24/34 with a maximum diameter of 11-20 20 mm (70.6%), 14/14 with a maximum diameter of >20 mm (100%) and 40/48 with a volume >= 0.2 cm(3) (83.3%). Regarding cancer lesions with a volume >= 0.2 cm(3) there was a significant difference in PCa detection rates between Gleason scores with predominant Gleason pattern 3 compared to those with predominant Gleason pattern 4 or 5 (75% versus 100%; P = 0.028). Conclusions. RTE is able to detect PCa of significant tumor volume and of predominant Gleason pattern 4 or 5 with high confidence, but is of limited value in the detection of small cancer lesions.
引用
收藏
页数:6
相关论文
共 25 条
[1]
The Index Lesion and the Origin of Prostate Cancer [J].
Ahmed, Hashim Uddin .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (17) :1704-1706
[2]
Value of enhanced transrectal ultrasound targeted biopsy for prostate cancer diagnosis: a retrospective data analysis [J].
Aigner, Friedrich ;
Schaefer, Georg ;
Steiner, Eberhard ;
Jaschke, Werner ;
Horninger, Wolfgang ;
Herrmann, Thomas R. W. ;
Nagele, Udo ;
Halpern, Ethan J. ;
Frauscher, Ferdinand .
WORLD JOURNAL OF UROLOGY, 2012, 30 (03) :341-346
[3]
Value of Real-Time Elastography Targeted Biopsy for Prostate Cancer Detection in Men With Prostate Specific Antigen 1.25 ng/ml or Greater and 4.00 ng/ml or Less [J].
Aigner, Friedrich ;
Pallwein, Leo ;
Junker, Daniel ;
Schaefer, Georg ;
Mikuz, Gregor ;
Pedross, Florian ;
Mitterberger, Michael Josef ;
Jaschke, Werner ;
Halpern, Ethan J. ;
Frauscher, Ferdinand .
JOURNAL OF UROLOGY, 2010, 184 (03) :913-917
[4]
COMPARISON OF MICROSCOPIC VASCULARITY IN BENIGN AND MALIGNANT PROSTATE TISSUE [J].
BIGLER, SA ;
DEERING, RE ;
BRAWER, MK .
HUMAN PATHOLOGY, 1993, 24 (02) :220-226
[5]
Multiparametric Ultrasound of the Prostate: Adding Contrast Enhanced Ultrasound to Real-Time Elastography to Detect Histopathologically Confirmed Cancer [J].
Brock, Marko ;
Eggert, Thilo ;
Palisaar, Rein Jueri ;
Roghmann, Florian ;
Braun, Katharina ;
Loeppenberg, Bjoern ;
Sommerer, Florian ;
Noldus, Joachim ;
von Bodman, Christian .
JOURNAL OF UROLOGY, 2013, 189 (01) :93-98
[6]
The Impact of Real-Time Elastography Guiding a Systematic Prostate Biopsy to Improve Cancer Detection Rate: A Prospective Study of 353 Patients [J].
Brock, Marko ;
von Bodman, Christian ;
Palisaar, Rein Jueri ;
Loeppenberg, Bjoern ;
Sommerer, Florian ;
Deix, Thomas ;
Noldus, Joachim ;
Eggert, Thilo .
JOURNAL OF UROLOGY, 2012, 187 (06) :2039-2043
[7]
Multiparametric magnetic resonance imaging for the detection and localization of prostate cancer: combination of T2-weighted, dynamic contrast-enhanced and diffusion-weighted imaging [J].
Delongchamps, Nicolas Barry ;
Rouanne, Mathieu ;
Flam, Thierry ;
Beuvon, Frederic ;
Liberatore, Mathieu ;
Zerbib, Marc ;
Cornud, Francois .
BJU INTERNATIONAL, 2011, 107 (09) :1411-1418
[8]
Gomez Veiga F., 2006, Archivos Espanoles de Urologia, V59, P1069
[9]
Computerized transrectal ultrasound of the prostate in a multicenter setup (C-TRUS-MS): detection of cancer after multiple negative systematic random and in primary biopsies [J].
Grabski, Bjoern ;
Baeurle, Leif ;
Loch, Annemie ;
Wefer, Bjoern ;
Paul, Udo ;
Loch, Tillmann .
WORLD JOURNAL OF UROLOGY, 2011, 29 (05) :573-579
[10]
A COMPARISON OF THE MORPHOLOGICAL FEATURES OF CANCER ARISING IN THE TRANSITION ZONE AND IN THE PERIPHERAL ZONE OF THE PROSTATE [J].
GREENE, DR ;
WHEELER, TM ;
EGAWA, S ;
DUNN, JK ;
SCARDINO, PT .
JOURNAL OF UROLOGY, 1991, 146 (04) :1069-1076