A compilation of silicon and thirty one trace elements measured in the natural river water reference material SLRS-4 (NRC-CNRC)

被引:110
作者
Yeghicheyan, D
Carignan, J
Valladon, M
Le Coz, MB
Le Cornec, F
Castrec-Rouelle, M
Robert, M
Aquilina, L
Aubry, E
Churlaud, C
Dia, A
Deberdt, S
Dupr, B
Freydier, R
Gruau, G
Hénin, O
de Kersabiec, AM
Macé, J
Marin, L
Morin, N
Petitjean, P
Serrat, E
机构
[1] Ctr Rech Petrog & Geochim, CNRS, SARM, F-54501 Vandoeuvre Les Nancy, France
[2] Lab Geochim, F-31400 Toulouse, France
[3] Geosci Rennes, F-35045 Rennes, France
[4] IRD, Lab Format Superficielles, F-93143 Bondy, France
[5] Univ Paris 06, Lab Geochim & Metallogenie, F-75252 Paris 05, France
[6] Univ La Rochelle, Ctr Commun Analyses, F-17000 La Rochelle, France
来源
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS | 2001年 / 25卷 / 2-3期
关键词
river water reference material; ICP-MS; silicon; rare earth elements; trace elements; compilation; SLRS-4;
D O I
10.1111/j.1751-908X.2001.tb00617.x
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
The natural river water certified reference material SLRS-4 (NRC-CNRC, National Research Council-Conseil National de Recherches Canada) has been routinely analysed for major and trace elements by six French laboratories. Most measurements were made using inductively coupled plasma-mass spectrometry. For silicon and thirty one trace elements (rare earth elements, Aq, B, Br, Cs, Ga, Ge, Li, R, Pd, Rb, Se, Th, Ti, Tl, W, Y and Zr), no certified values are assigned by NRC-CNRC. We propose some compilation values and related uncertainties according to the results obtained by the different laboratories.
引用
收藏
页码:465 / 474
页数:10
相关论文
共 19 条
[1]   A routine method for oxide and hydroxide interference corrections in ICP-MS chemical analysis of environmental and geological samples [J].
Aries, S ;
Valladon, M ;
Polvé, M ;
Dupré, B .
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2000, 24 (01) :19-31
[2]   High-temperature hydraulic high-pressure nebulization: A recent nebulization principle for sample introduction [J].
Berndt, H ;
Yanez, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :703-712
[3]  
Bouhnik-Le Coz M., 2001, VALIDATION PROTOCOLE
[4]  
BROOKINS DG, 1989, REV MINERAL, V21, P201
[5]  
Brookins DG, 1988, EH PH DIAGRAMS GEOCH
[6]   Routine analyses of trace elements in geological samples using flow injection and low pressure on-line liquid chromatography coupled to ICP-MS: A study of geochemical reference materials BR, DR-N, UB-N, AN-G and GH [J].
Carignan, J ;
Hild, P ;
Mevelle, G ;
Morel, J ;
Yeghicheyan, D .
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2001, 25 (2-3) :187-198
[7]  
Date AR, 1989, APPL INDUCTIVELY COU
[8]  
FEINBERG M, 1996, VALIDATION METHODES
[9]  
Fleet A.J., 1984, Developments in Geochemistry, V2, P343, DOI DOI 10.1016/B978-0-444-42148-7
[10]   ANALYTICAL IMPROVEMENT OF PNEUMATIC NEBULIZATION IN ICP-MS BY DESOLVATION [J].
JAKUBOWSKI, N ;
FELDMANN, I ;
STUEWER, D .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (01) :107-118