A new method for the model-independent assessment of thickness in three-dimensional images

被引:1508
作者
Hildebrand, T [1 ]
Ruegsegger, P [1 ]
机构
[1] SWISS FED INST TECHNOL,CH-8044 ZURICH,SWITZERLAND
来源
JOURNAL OF MICROSCOPY-OXFORD | 1997年 / 185卷
关键词
distance transformation; mean thickness; micro-CT; stereology; structural parameters; thickness distribution; three-dimensional morphometry; trabecular bone structure;
D O I
10.1046/j.1365-2818.1997.1340694.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
Three-dimensional (3-D) structural parameters derived from lower-dimensional measurements using indirect morphometric methods may be strongly biased if the measured objects deviate from the assumed structure model. With the introduction of 3-D microscopic measuring techniques it is possible to obtain a complete depiction of complex spatial structures. As a consequence, new 3-D methods have recently been developed for the estimation of morphometric parameters such as volume, surface area and connectivity by direct processing of the 3-D images, Structure thickness is an important morphometric parameter which is usually defined for specific structure models only, In this paper we propose a general thickness definition for arbitrary structures allowing us to calculate the mean structure thickness and the thickness distribution of 3-D objects in a direct way and independently of an assumed structure model. Additionally, an efficient implementation for the practical usage of the method is described using distance transformation, The new method is applied to trabecular bone structures measured with a 3-D micro-computed tomography system.
引用
收藏
页码:67 / 75
页数:9
相关论文
共 31 条
[1]   DISTANCE TRANSFORMATIONS IN ARBITRARY DIMENSIONS [J].
BORGEFORS, G .
COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1984, 27 (03) :321-345
[2]  
CRUZ-ORIVE L M, 1979, Biometrical Journal, V21, P717, DOI 10.1002/bimj.4710210803
[3]   RECENT STEREOLOGICAL METHODS FOR CELL BIOLOGY - A BRIEF SURVEY [J].
CRUZORIVE, LM ;
WEIBEL, ER .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (04) :L148-L156
[4]   EUCLIDEAN DISTANCE MAPPING [J].
DANIELSSON, PE .
COMPUTER GRAPHICS AND IMAGE PROCESSING, 1980, 14 (03) :227-248
[5]   THE DIRECT EXAMINATION OF 3-DIMENSIONAL BONE ARCHITECTURE INVITRO BY COMPUTED-TOMOGRAPHY [J].
FELDKAMP, LA ;
GOLDSTEIN, SA ;
PARFITT, AM ;
JESION, G ;
KLEEREKOPER, M .
JOURNAL OF BONE AND MINERAL RESEARCH, 1989, 4 (01) :3-11
[6]   MEASUREMENT OF MEAN TRABECULAR PLATE THICKNESS BY A NEW COMPUTERIZED METHOD [J].
GARRAHAN, NJ ;
MELLISH, RWE ;
VEDI, S ;
COMPSTON, JE .
BONE, 1987, 8 (04) :227-230
[7]   CONSTRUCTING DISCRETE MEDIAL AXIS OF 3-D OBJECTS [J].
Goldak, John A. ;
Yu, Xinhua ;
Knight, Alan ;
Dong, Lingxian .
INTERNATIONAL JOURNAL OF COMPUTATIONAL GEOMETRY & APPLICATIONS, 1991, 1 (03) :327-339
[8]   VOLUME AND SURFACE-AREA MEASUREMENT OF VIABLE CHONDROCYTES IN-SITU USING GEOMETRIC MODELING OF SERIAL CONFOCAL SECTIONS [J].
GUILAK, F .
JOURNAL OF MICROSCOPY, 1994, 173 :245-256
[9]   SOME NEW, SIMPLE AND EFFICIENT STEREOLOGICAL METHODS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS - REVIEW ARTICLE [J].
GUNDERSEN, HJG ;
BENDTSEN, TF ;
KORBO, L ;
MARCUSSEN, N ;
MOLLER, A ;
NIELSEN, K ;
NYENGAARD, JR ;
PAKKENBERG, B ;
SORENSEN, FB ;
VESTERBY, A ;
WEST, MJ .
APMIS, 1988, 96 (05) :379-394
[10]   THE NEW STEREOLOGICAL TOOLS - DISECTOR, FRACTIONATOR, NUCLEATOR AND POINT SAMPLED INTERCEPTS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS [J].
GUNDERSEN, HJG ;
BAGGER, P ;
BENDTSEN, TF ;
EVANS, SM ;
KORBO, L ;
MARCUSSEN, N ;
MOLLER, A ;
NIELSEN, K ;
NYENGAARD, JR ;
PAKKENBERG, B ;
SORENSEN, FB ;
VESTERBY, A ;
WEST, MJ .
APMIS, 1988, 96 (10) :857-881