Retrieval analysis of three generations of Biolox® femoral heads: Spectroscopic and SEM characterisation

被引:53
作者
Affatato, S. [1 ]
Modena, E. [2 ]
Toni, A. [1 ]
Taddei, P. [2 ]
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, I-40136 Bologna, Italy
[2] Univ Bologna, Sez Chim & Propedeut Biochim, Dipartimento Biochim G Moruzzi, Bologna, Italy
关键词
Biolox (R); Biolox (R) forte; Biolox (R) delta; SEM; Raman spectroscopy; Fluorescence; PHOTOLUMINESCENCE INVESTIGATIONS; RESIDUAL-STRESSES; RAMAN-SPECTRA; ZIRCONIA; WEAR; TRANSFORMATION; FRACTURE;
D O I
10.1016/j.jmbbm.2012.04.003
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Wear and osteolysis continue to be the major reasons for revision surgery in Total Hip Arthroplasty. The introduction of the ceramic-on-ceramic bearings eliminates the problem of polyethylene wear debris. During the last 40 years, three generations of Biolox (R) ceramics were developed (Biolox (R), Biolox (R) forte, and Biolox (R) delta), each better than the previous from the density, grain size and purity point of view. We conducted a retrieval study on 15 Biolox (R) femoral heads (Biolox (R), Biolox (R) forte, and Biolox (R) delta) articulating against liners of the same type. Surface properties and residual stress were assessed using SEM, fluorescence and Raman spectroscopy. At SEM examination, the Biolox (R) delta retrievals showed a lower wear than the previous generations. The fluorescence measurements suggested different wear mechanisms in the three sets of retrievals. Micro-cracking was predominant in Biolox (R), while in Biolox (R) forte and Biolox (R) delta a wider range of residual stress values was observed upon wear. Surface polishing was observed only in Biolox (R) and Biolox (R) forte. Raman spectroscopy of Biolox (R) delta femoral heads showed a progressive improvement in material composition. Wear induced a tetragonal to monoclinic transformation. The Raman results on the retrievals, here reported for the first time, allowed to validate the in vitro ageing protocols proposed in the literature to simulate the effects of the in vivo wear. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:118 / 128
页数:11
相关论文
共 38 条
[1]
LONG-TERM RESULTS OF UNCEMENTED ALUMINA ACETABULAR IMPLANTS [J].
BOEHLER, M ;
KNAHR, K ;
PLENK, H ;
WALTER, A ;
SALZER, M ;
SCHREIBER, V .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01) :53-59
[2]
High strength and toughness alumina matrix composites by transformation toughening and 'in situ' platelet reinforcement (ZPTA) - The new generation of bioceramics [J].
Burger, W ;
Richter, HG .
BIOCERAMICS, 2000, 192-1 :545-548
[3]
How have alternative bearings (such as metal-on-metal, highly cross-linked polyethylene, and ceramic-on-ceramic) affected the prevention and treatment of osteolysis? [J].
Callaghan, John J. ;
Cuckler, John M. ;
Huddleston, James I. ;
Galante, Jorge O. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2008, 16 :S33-S38
[4]
Ceramtec, 2011, BIOLOX DELT NAN ARTH
[5]
What future for zirconia as a biomaterial? [J].
Chevalier, J .
BIOMATERIALS, 2006, 27 (04) :535-543
[6]
Chevalier J, 1999, J AM CERAM SOC, V82, P2150
[7]
Reliability assessment in advanced nanocomposite materials for orthopaedic applications [J].
Chevalier, Jerome ;
Taddei, Paola ;
Gremillard, Laurent ;
Deville, Sylvain ;
Fantozzi, Gilbert ;
Bartolome, J. F. ;
Pecharroman, C. ;
Moya, J. S. ;
Diaz, L. A. ;
Torrecillas, R. ;
Affatato, Saverio .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (03) :303-314
[8]
On the kinetics and impact of tetragonal to monoclinic transformation in an alumina/zirconia composite for arthroplasty applications [J].
Chevalier, Jerome ;
Grandjean, Sylvie ;
Kuntz, Meinhard ;
Pezzotti, Giuseppe .
BIOMATERIALS, 2009, 30 (29) :5279-5282
[9]
CHRISTIAN JW, 1965, THEORY TRANSFORMATIO, P525
[10]
MEASUREMENT OF THE CRYSTALLOGRAPHICALLY TRANSFORMED ZONE PRODUCED BY FRACTURE IN CERAMICS CONTAINING TETRAGONAL ZIRCONIA [J].
CLARKE, DR ;
ADAR, F .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1982, 65 (06) :284-288